Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
Functional and Radiological Outcome of Unstable Intertrochanteric Fracture Post Dynamic Hip Screw Fixation
Muhammad T Lakho1, Asif A Jatoi1, Muhammad Khanzada Azfar2
1Orthopedics, Jinnah Postgraduate Medical Center, Karachi, PAK.
Abstract:
Introduction Intertrochanteric fractures are the most frequently operated fracture type and have the highest postoperative fatality rate. The most commonly used devices are the dynamic hip screw (DHS) with side plate assemblies and proximal femoral nail (PFN). The aim of this study was to determine the functional and radiological outcome of unstable intertrochanteric fracture post DHS fixation at a tertiary care hospital in Karachi, Pakistan. Methods A study was carried out in the department of orthopedics at the Jinnah Postgraduate Medical Center (JPMC), from 12th June 2016 to 8th September 2017. A total of 106 patients between 18 and 75 years of age with unstable intertrochanteric fracture were included. Those patients who had multiple injuries and open fractures, subtrochanteric fractures, intracapsular fractures neck of femur, pathological fractures and patients who were non-ambulatory prior to their injury were excluded. Functional outcomes were measured both during pain using the visual analog scale and range of motion on goniometer between 80 and 100 degrees. Satisfactory outcomes were measured after three months. Results A total of 106 patients with the radiological diagnosis of the unstable intertrochanteric fracture having post DHS fixation were included in this study. Out of which, 69.8% (74) were males and the mean age was 66.61 ± 7.79 years over the range of 50 to 80 years. Patients with type II diabetes were 22.6% (24) with a mean duration of 4.3 ± 8.37 years. At the end of three months, no pain was reported in 82.1% (87) patients and 85.8% (91) patients had normal function. The satisfactory radiological outcome was observed in 86.8% (92) patients. Overall, acceptable outcomes were observed in 81.1% (86) patients at the end of three months. Conclusion The treatment of unstable intertrochanteric fracture with dynamic hip screw (DHS) fixation results in better outcomes. In our study, we observed acceptable outcomes in a vast majority, 81.1%, of patients after three months of DHS fixation of the unstable intertrochanteric fracture.
More Related Videos
04:19Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
06:58Method and Instrumented Fixture for Femoral Fracture Testing in a Sideways Fall-on-the-Hip Position
Published on: August 17, 2017
Related Concept Videos
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Screw: Problem Solving
To evaluate the...
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
Radiological Investigation I: X-ray and CT
Predicting Reaction Outcomes
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...