Larger Valve Size is Associated with Permanent Pacemaker Implantation in Edwards SAPIEN 3™ Transcatheter Aortic
Mansoor Ahmad1, Jay N Patel2, Minchul Kim1
1Internal Medicine, University of Illinois College of Medicine at Peoria, Peoria, USA.
Background:
Transcatheter aortic valve replacement (TAVR) can be complicated with a high-degree atrioventricular (AV) block requiring a permanent pacemaker (PPM) in 5% - 25% of patients. TAVR valve size is a modifiable risk factor for permanent pacemaker implantation (PPI) after TAVR. We studied the association of valve size in PPI with Edwards SAPIEN 3™ (ESV3) (Edwards Lifesciences LLC, Irvine, CA, USA) TAVR valves.
Method:
This is a single-center retrospective cohort analysis of 449 patients undergoing TAVR from December 2012 to April 2018. We excluded patients with TAVR valve types other than the ESV3 (113 patients) and those with prior PPM or implantable cardioverter defibrillator (37 patients). Patients with an aborted procedure and surgical conversion were also excluded (16). Data of 14 patients with missing values for different clinical variables were excluded as well. The final sample size was 269. The primary outcome was PPI. Statistical analysis was done using Chi-square, T-test, and multivariate regression analysis. Multivariate analysis was done for comparison between different clinical variables.
Results:
Of the 269 patients (50.6% males; mean age of 79.5 ± 8.7 years; mean Society of Thoracic Surgeons (STS) score: 6.2), PPI was seen in 17 patients (6.3%). Time to PPI was 1.3 days. PPI was significantly high in patients with prior conduction defects (p = 0.016). There was a positive relationship between PPI and valve size for ESV3. PPI was seen in eight patients (47%) with 29 mm valves, six patients (35%) with 26 mm valves, three patients (17%) with 23 mm valves, and none with 20 mm valves. When taken as a reference, 23 mm valves had a significantly lower PPI compared with 29 mm valves (eight versus three; p = 0.04).
Conclusion:
Larger valve size is a possible risk factor for a high-degree AV in patients receiving ESV3.
Related Concept Videos
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Mitral Valve Prolapse I: Introduction
Mitral Valve Prolapse II: Assessment and Management
Mitral Valve Prolapse III: Nursing Management
Ethnic Identity within a Larger Culture
Cell Size
Surface Area
Cells can take in nutrients and water via diffusion through the plasma membrane itself or through specific channels in the membrane. The area of the membrane surrounding...