Multidirectional Shoulder Instability With Bone Loss and Prior Failed Latarjet Procedure: Treatment With Fresh Distal

Liam A Peebles1, Zachary S Aman1, Fletcher R Preuss2

  • 1Steadman Philippon Research Institute, Vail, Colorado, U.S.A.

Related Concept Videos

Muscles of the Shoulder01:23

Muscles of the Shoulder

The muscles surrounding the shoulder girdle, including the clavicle and scapula, primarily stabilize the scapula. This stable base allows other muscles to move the humerus effectively. Scapular movements often mirror those of the humerus and extend its range of motion. For instance, raising the arm above the head would not be feasible without simultaneous upward rotation of the scapula.
Anterior Thoracic Muscles
The anterior thoracic muscles include the serratus anterior, subclavius, and...
9.1K
Microtubule Instability02:17

Microtubule Instability

Microtubules are hollow cylindrical filaments having a diameter of approximately 25 nm and a length that varies from 200 nm to 25 μm. GTP-bound tubulin subunits form αβ-heterodimers for microtubule assembly. These core building blocks interact longitudinally, polymerizing into protofilaments. The protofilaments then interact with one another through lateral bonding forces to form stable cylindrical microtubules. These cylindrical filaments are dynamic as they undergo repeated...
6.1K
Hypothesis: Accept or Fail to Reject?01:17

Hypothesis: Accept or Fail to Reject?

The outcome of any hypothesis testing leads to rejecting or not rejecting the null hypothesis. This decision is taken based on the analysis of the data, an appropriate test statistic, an appropriate confidence level, the critical values, and P-values. However, when the evidence suggests that the null hypothesis cannot be rejected, is it right to say, 'Accept' the null hypothesis?
There are two ways to indicate that the null hypothesis is not rejected. 'Accept' the null...
29.4K
Line Loss01:10

Line Loss

The different configurations of source-load connections include wye (star) and delta connections. The relationship between line and phase voltages and currents varies depending on the configuration. When the source is supplying power, it is transmitted through the wires to the load, and during this transmission, some power is absorbed by the wires, leading to line loss.
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
518
Reducing Line Loss01:18

Reducing Line Loss

In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
371
Segregation in Fresh Concrete01:16

Segregation in Fresh Concrete

Segregation in fresh concrete is a phenomenon where the components of the concrete mix separate, leading to uneven distribution and compromised structural integrity. This separation typically occurs when concrete is subjected to excessive horizontal movement within forms, or when it is dropped from considerable heights or forced through narrow, winding paths. As a result, heavier coarse aggregate particles settle at the bottom, while lighter, finer materials such as cement and water rise to the...
566