Intentional switch between 1.5-mm and 1.25-mm burrs along with switch between rotawire floppy and extra-support for
Yousuke Taniguchi1, Kenichi Sakakura1, Yasuhiro Mukai1
1Division of Cardiovascular Medicine, Saitama Medical Center, Jichi Medical University, Saitama, Japan.
Abstract:
Rotational atherectomy (RA) is considered to be the last resort for a severely calcified coronary artery lesion. Severe complications such as vessel perforation or burr entrapment is closely associated with forceful burr manipulation during RA. The instructions for use of Rotablator (Boston Scientific, Marlborough, MA, USA) prohibit forceful burr manipulation when rotational resistance occurs. Nevertheless, RA operators tend to forcefully manipulate the burr if it cannot cross the lesion, because there has been no established strategy for an uncrossable lesion. We present a case with a severely calcified coronary lesion, which was uncrossable by a burr 1.5 mm with RotaWire Floppy (Boston Scientific). We intentionally switched 2 burrs (1.5-mm and 1.25-mm) and 2 RotaWires (Floppy and Extra-support) to cross the lesion. Uniquely, we downsized the burr (from 1.5-mm to 1.25-mm) initially for better penetration force, and upsized the burr (from 1.25-mm to 1.5-mm) finally for better contact to the calcification within the lesion. Our case suggests that 4 different types of combinations might work in a mutually complementary manner for an uncrossable calcified lesion. <Learning Objective: In rotational atherectomy, severe complications such as vessel perforation or burr entrapment are closely associated with forceful burr manipulation. We present a case with a severely calcified coronary lesion, which was uncrossable by a burr 1.5 mm with RotaWire Floppy. We intentionally switched 2 burrs and 2 RotaWires to cross the lesion. Our case suggests that 4 different types of combinations might work in a mutually complementary manner for an uncrossable calcified lesion.>.
Related Concept Videos
Switching of BJT
Cut-off Mode ("Off" State): In this state, both the emitter-base and collector-base junctions are...
Self-Help Support Groups
Accessibility and Cost-Effectiveness
One of the primary strengths of self-help...
Coronary Circulation
Coronary circulation begins at the base of the aorta, where two main arteries arise—the left and right coronary arteries. These arteries encircle the heart in the coronary sulcus and supply the...
Support Reactions
The purpose of the supports is to prevent the translational motion of the system by applying an equal and opposite force and to prevent the system's rotation by applying...
Support Reactions in Three Dimensions
Ball and Socket Joint is one of the supports allowing free rotation about any axis. This freedom of rotation is...
Coronary Artery Disease I: Introduction