Related Experiment Video
Updated: Jan 23, 2026

Multispectral Optoacoustic Tomography for Functional Imaging in Vascular Research
Published on: June 8, 2022
Wave front analysis for enhanced time-domain beamforming of point-like targets in optoacoustic imaging using a linear
Marc Fournelle1, Wolfgang Bost1
1Fraunhofer Institut für Biomedizinische Technik, Ensheimer Str. 48, D-66386 Sankt Ingbert, Germany.
Abstract:
Using linear array transducers in combination with state-of-the-art multichannel electronics allows to perform optoacoustic imaging with frame rates only limited by the laser pulse repetition frequency and the acoustic time of flight. However, characteristic image artefacts resulting from the limited view and a lower SNR when compared to systems based on single-element focused transducers represent a burden for the clinical acceptance of the technology. In this paper, we present a new method for the improvement of image quality based on the analysis of the signal amplitudes along summation curves during the delay-and-sum beamforming process (DAS). The algorithm compares amplitude distributions along wave fronts with theoretical patterns from optoacoustic point sources. The method was validated on simulated and experimental phantom as well as in-vivo data. An improvement of the lateral resolution by more than a factor of two when comparing conventional DAS and our approach could be shown (numeric and experimental phantom data). For instance, on experimental data from a wire phantom, a PSF in the range of 0.18-0.22 mm was obtained with our approach against 0.48 mm for standard DAS. Furthermore, the SNR of a subcutaneous vessel 2.5 mm below the skin surface was improved by about 30 dB when compared to standard DAS.
More Related Videos
09:56Universal Hand-held Three-dimensional Optoacoustic Imaging Probe for Deep Tissue Human Angiography and Functional Preclinical Studies in Real Time
Published on: November 4, 2014
08:54Measurements of Waves in a Wind-wave Tank Under Steady and Time-varying Wind Forcing
Published on: February 13, 2018
Related Concept Videos
Linear Approximation in Time Domain
For a simple pendulum with a mass evenly distributed along its length and the center of mass located at half the pendulum's length,...
Linear Approximation in Frequency Domain
In contrast, nonlinear systems do not inherently possess these properties. However, for small deviations around an operating point, a nonlinear system can often be approximated as linear....
Linear time-invariant Systems
The input-output behavior of an LTI system can be fully defined by its response to an impulsive excitation at its input. Once this impulse response is known, the system's reaction to any other input can be...
Conservation of Protein Domains Over Different Proteins
A limited set of protein domains often duplicate and recombine during evolution. These domains can be organized in different combinations to...
Voltammetric Techniques: Linear-Scan (E vs Time)
Time-Domain Interpretation of PD Control
Consider the example of control of motor torque. Initially, a positive...