Published on: April 5, 2019
A Portable Device for Rapid Detection of Human Serum Albumin using an immunoglobulin-coating-based Magnetoelastic
Shengbo Sang1, Yuchao Li1, Xing Guo1
1MicroNano System Research Center, Key Laboratory of Advanced Transducers and Intelligent Control System of Ministry of Education and Shanxi Province, College of Information & Computer Engineering, Taiyuan University of Technology, Taiyuan, 030024, China.
Abstract:
Abnormal protein concentration levels in human body fluids, such as urine, serum etc., are considered to associate with disease states, providing essential information for the pre-clinical diagnosis. This paper presents a wireless immunoglobulin-coated magnetoelastic (ME) biosensor for fast, cost-effective detections of human serum albumin (HSA) with small sample volumes at a microliter scale. This is the first portable resonant sensor based on magnetostrictive effect that can monitor different molecular states of HSA. Anti-HSA Immunoglobulin G (IgG) was immobilized on the surface of the ME sensor to selectively capture HSA. The rapid conjugation between the antibody and antigen changed the sensor surface states and thus induced resonance frequency shifts (RFS), which were monitored in real time for the qualitative and quantitative analysis of HSA. This paper brings forward a System on Chip (SoC)-based system architecture to realize the function of RFS sampling. The performance of the portable device was validated to be comparable to that of the Vector Network Analyzer (VNA) AV3620 using different concentrations of HSA solution. The RFS were linearly proportional to the HSA concentrations in the range from 0.1 to 100 μg/mL with a linearity up to 0.998, a sensitivity of 8.70 Hz/μg.mL-1 and a detection limit of 0.039 μg/mL, indicating good feasibility of this method. Meanwhile, the response of this portable ME biosensor was quick and specific to HSA targets. This ME biosensor shows high potential to be used in diagnosing abnormal HSA.
Related Concept Videos
Immunoglobulin-like Cell Adhesion Molecules
Ig-CAMs exhibit either homophilic binding (to other Ig-CAMs) or heterophilic binding (to other ligands such as integrins). While most Ig-CAMs...
Clathrin Coated Vesicles
COP Coated Vesicles
Coat Assembly and GTPases
Coat assembly depends on the local availability of phosphatidylinositol phosphates or PIPs and GTP-binding proteins. Adaptor proteins, which link the coat proteins to the membrane, bind to these PIPs and play a crucial role in controlling...
Pinching-off of Coated Vesicles
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration