Related Experiment Video
Updated: Jan 23, 2026

Minimal Erythema Dose MED Testing
Published on: May 28, 2013
Outcome measurement instruments for erythema associated with incontinence-associated dermatitis: Systematic review
Dorien De Meyer1, Sabrina Gabriel2, Jan Kottner1,2
1Skin Integrity Research Group (SKINT), University Centre for Nursing and Midwifery, Department of Public Health and Primary Care, Faculty of Medicine and Health Sciences, Ghent University, Ghent, Belgium.
Aim:
To: (a) examine which outcome measurement instruments for erythema associated with incontinence-associated dermatitis (IAD) with supporting evidence about measurement properties are available; (b) evaluate the methodological quality of the studies and the quality of the measurement properties; and (c) identify eligible instruments to measure erythema in incontinence-associated dermatitis research.
Design:
Systematic review.
Data Sources:
MEDLINE, EMBASE, CINAHL and CENTRAL were systematically searched until July 2018 (update December 2018). Additional input was gathered from 151 incontinence-associated dermatitis experts. Cited and citing references of included studies were screened.
Review Methods:
The COSMIN Risk of Bias checklist was applied to evaluate the methodological quality of the studies. Reported measurement properties were rated against criteria for good measurement properties.
Results:
Fourteen studies, describing 10 measurement instruments, were included. In five instruments, erythema was captured as a separate concept, two studies provided empirical evidence about the measurement properties. The most studied measurement properties were reliability (9 studies), measurement error (4 studies) and criterion validity (4 studies). In one study, internal consistency was examined.
Conclusion:
No instrument measuring exclusively erythema associated with incontinence-associated dermatitis exists. There is no single composite incontinence-associated dermatitis measurement instrument that outperforms others. Development or adaption of an instrument to measure erythema associated with incontinence-associated dermatitis is one option to solve this challenge.
Impact:
The evidence about measurement properties of instruments measuring erythema associated with incontinence-associated dermatitis has not been summarized to date. The lack of an instrument should trigger activities to measure this domain accurately in future clinical trials.
Related Concept Videos
Uncertainty in Measurement: Reading Instruments
Electronic Distance Measuring Instruments
Review and Preview
Percentiles are a type of fractile that partition data into...
Review and Preview
Instrument Transformers
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...

