Related Experiment Video
Updated: Jan 23, 2026

Impact of Fabrication Techniques and Polishing Procedures on Surface Roughness of Denture Base Resins
Published on: January 17, 2025
Impact Strength and Dimensional Accuracy of Heat-Cure Denture Base Resin Reinforced With ZrO2 Nanoparticles: An In
S Sajida Begum1, R Ajay2, V Devaki2
1Department of Prosthodontics and Crown and Bridge, Vinayaka Missions Sankarachariyar Dental College, Salem, Tamil Nadu, India.
Background:
Polymerization shrinkage and fracture are the two common trouble shoots with denture base resins. Polymerization shrinkage affects the dimensional accuracy and fit of the prosthesis. The effect of zirconia (ZrO2) nanoparticles on polymerization shrinkage is not documented yet.
Purpose:
The aim and objective of this study were to evaluate the impact strength and dimensional accuracy of heat-cured poly methyl methacrylate (PMMA) on reinforcement with ZrO2 nanoparticles.
Materials And Methods:
Conventional heat-cure denture base resin (control) and the polymer reinforced with 3, 5, and 7 wt% of ZrO2 nanoparticles were prepared and used in this study. Forty bar-shaped specimens were prepared and tested for impact strength using Charpy's type impact tester. Forty denture bases were fabricated and checked for dimensional accuracy by measuring the distance between the denture base and the cast in two different sections using the travelling microscope.
Results:
The impact strength decreased with increased concentration of ZrO2 and found to be least at 7 wt% concentration (2.01 ± 0.26 J/mm2). The distance between the denture base and the cast significantly decreased both in the posterior palatal seal region (0.060 ± 0.007 cm) and mid-palatine section region (0.057 ± 0.006 cm) with ZrO2 nanoparticles reinforcement and was found to be least at 7 wt% concentration.
Conclusion:
Reinforcement of heat-cured PMMA with ZrO2 nanoparticles significantly increased the dimensional accuracy and decreased the impact strength.
More Related Videos
16:30Application of Light-cured Dental Adhesive Resin for Mounting Electrodes or Microdialysis Probes in Chronic Experiments
Published on: July 30, 2007
06:022-Methacryloyloxyethyl Phosphorylcholine Polymer Treatment of Complete Dentures to Inhibit Denture Plaque Deposition
Published on: December 26, 2016
Related Concept Videos
Strength and Heat of Hydration
The heat of hydration for each cement compound is significant; for instance, tricalcium aluminate (C3A) and...
Impact Strength of Concrete
Relative Strengths of Conjugate Acid-Base Pairs
Acid and Bases: Ka, pKa, and Relative Strengths
Curing of Concrete
Curing Methods