Bacterial contamination of automated MRI contrast injectors in clinical routine
Juliane Goebel1, Joerg Steinmann2,3, Evelyn Heintschel von Heinegg3
1Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Germany.
Abstract:
Aim: To quantify the frequency of bacterial contamination of the injected contrast agent/saline solution by an automated contrast injection system, and to evaluate whether usage of a novel tube system can reduce it. Methods: For bacterial contamination quantification two identical automated piston pump MRI contrast injectors were used in combination with a standard tube system. 3-5 ml of the contrast agent/saline solution was collected from the system prior to its connection to the patients' venous cannula in 104 consecutive patients. To test, whether a novel tube system reduces contamination, a tube system with shielded screw connections was used with the same contrast injectors and contrast agent/saline samples were collected in further 101 patients. Specimens were microbiologically analyzed. Frequencies of contamination were compared using Fisher exact test. Results: With the standard tube system, bacterial contamination was observed in 5.8% (6 out of 104 specimens). With the novel tube system, contamination was observed in 2.0% (2 out of 101 specimens, p=0.280). Staphylococcus epidermidis was the most common germ (5 cases) followed by Micrococcus luteus (2 cases) and Oligella ureolytica (1 case). Conclusion: Bacterial contaminations of MRI contrast injectors occurred in a non-negligible frequency especially with S. epidermidis. A trend towards reduced bacterial contamination was seen when a novel tube system with shielded screw connections was used.
Related Concept Videos
Contaminants and Errors
Another key consideration is determining the appropriate number of samples required to...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Bacterial Signaling
Bacterial Transformation
Griffith made an unexpected discovery when he killed the pathogenic strain and mixed its remains with the live, non-pathogenic strain. Not only did the mixture kill host mice, but it also contained living pathogenic bacteria that...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Nursing Clinical Information System
A Nursing Clinical Information System (NCIS) is a specialized type of healthcare information system tailored to meet the unique needs of nursing practice. It incorporates the principles of nursing informatics to streamline information management and improve the quality of care delivery.
Critical attributes of NCIS include: