Related Experiment Video
Updated: Jan 23, 2026

A New Ex Vivo Model for the Evaluation of Endoscopic Submucosal Injection Material Performance
Published on: October 19, 2018
Colorectal endoscopic submucosal dissection can be efficiently performed by a trainee with use of a simple traction
Daisuke Ide1,2, Shoichi Saito1, Tomohiko Richard Ohya3
1Department of Lower Gastrointestinal Medicine, The Cancer Institute Hospital of Japanese Foundation for Cancer Research, Tokyo, Japan.
Abstract:
Background and study aims Colorectal endoscopic submucosal dissection (ESD) is technically challenging owing to submucosal fibrosis and difficult endoscope manipulation. Therefore, various traction methods have been reported. We often use a simple looped nylon thread attached to a clip to assist with dissection. We assessed the feasibility of mentor-guided colorectal ESD using this traction device (TD). Patients and methods From December 2017 to March 2018, we retrospectively reviewed outcomes of 101 colorectal ESDs performed by two groups of endoscopists (A, 5 endoscopists with colorectal ESD experience of < 50 cases; B, 5 endoscopists with experience of > 300 cases). Group A was further divided into two subgroups that performed ESD with or without TD. Results No significant difference was observed in ESD completion rates (86.1 % [62/72] vs. 96.6 % [28/29]; odds ratio [OR], 0.22; 95 % confidence interval [CI], 0.005 - 1.71; P = 0.17) or procedure times (52.0 min vs. 40.0 min; P = 0.27) and adverse event rates between groups A and B. The rate of TD use was significantly higher in group A than in group B (44.4 % [32/72] vs. 20.7 % [6/29]; OR, 3.03; CI, 1.04 - 10.23; P = 0.03). The completion rate was not different between the two subgroups of group A (with vs. without TD) (81.2 % [26/32] vs. 90.0 % [36/40]; OR, 0.49; CI, 0.09 - 2.29; P = 0.32); however, the proportion of fibrosis cases was significantly higher in the TD-use group (46.8 % [15/32] vs. 22.5 % [9/40]; OR, 2.99; CI, 0.98 - 9.59; P = 0.03). Conclusion Mentor-guided colorectal ESD using TD was performed efficiently, safely, and in a manner comparable to that of experts.
More Related Videos
Related Concept Videos
Performing a Simple Data Analysis using MS-Excel Function
SUM: This function calculates the total sum of a range of values. It's the foundation for aggregating data, essential for determining overall trends and totals in datasets.
AVERAGE: It computes the mean value of a given set of numbers, providing a quick insight into the central...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Endoscopic Procedures II: Colonoscopy
Endoscopic Procedures V: ERCP
Patient...
Simple Pendulum
The period of a simple pendulum depends on two factors: its length and the acceleration due to gravity. The period is completely independent of any other factors, such as mass or maximum displacement. For small displacements, a pendulum is...

