Computed Tomography Postprocessing for Abdominal Aortic Aneurysm Lumen Recognition in Unenhanced Examinations
Related Experiment Video
Updated: Jan 23, 2026

Porcine Model of Infrarenal Abdominal Aortic Aneurysm
Published on: November 21, 2019
Enrico Cieri1, Gioele Simonte1, Danilo Costarelli2
1Department of Surgical and Biomedical Sciences, University of Perugia, Perugia, Italy.
Introduction:
Contrast medium (CM) use in computed tomography (CT) is limited by nephrotoxicity and possible allergic reactions. The purpose of this study is to introduce a tool for the diagnosis of abdominal aortic aneurysms (AAAs) by avoiding the use of CM.
Methods:
With and without CM CTs of patients with AAA were evaluated. A mathematical algorithm was implemented to allow visualization of the inner aortic lumen in the series without CM. The first step of the algorithm consisted in manually highlighting a squared region of interest (ROI) close to the target aortic area. The rest of the algorithm is completely automated and performs the following flow of operations: The "Kantorovich" algorithm is applied to the ROI for image enhancement. Then, a wavelet decomposition method is applied to identify the different frequency components of the image. Exploiting the wavelet decomposition, the system selects the low-frequency components of the image, corresponding to the major structures. Thresholding method, based on the analysis of the gray-level histogram, is then performed to extract the contours of the vessel. At this point, the extraction of the pervious area is completed. Final images were compared with the contrast enhanced scans, valued as gold standard. To validate the algorithm, an analysis of the results has been performed considering the following types of error: En = #m/#ROI ΔA = |1-(#CM/#CEX)| (#m = number of misclassified pixels; #ROI = number of pixels in the ROI; #CM = number of pixels belonging to the CM; #CEX = extracted areas). En provided a measure on the pixels wrongly classified, and ΔA the difference of extracted areas.
Results:
The algorithm was applied to 233 CT images. Extracted images were compared with the ones with CM. Mean values of the numerical errors ranged from 0.12 to 0.17 for En and 0.11 to 0.35 for ΔA. For all the 233 CT images in the analyzed sequences, the mean error was 0.14 (En) and 0.28 (ΔA).
Conclusions:
The developed mathematical algorithm allows to detect the position of the vessel lumen and to extract its contours with a good accuracy. Our experience shows encouraging results and suggests a possible future clinical application to reduce CT CM use.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Aneurysm I: Introduction
Abdominal Aorta
The celiac trunk, a singular artery, divides into the left gastric artery, which...
Aneurysm III: Interprofessional Care
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...