Haeyoung Joe1, Ki Joo Pahk2, Shinsuk Park3
1Center for Bionics, Biomedical Research Institute, Korea Institute Science and Technology (KIST), 5, Hwarangro 14-gil, Seongbuk-gu, Seoul 02792, Republic of Korea; Human-Machine Systems Laboratory, Dept. of Mechanical Engineering, Korea University, 145, Anam-ro, Seongbuk-gu, Seoul 02841, Republic of Korea.
Abstract:
Low-Intensity Focused Ultrasound (LIFU) has recently been considered as a promising neuromodulation technique because it can noninvasively stimulate the brain with a high spatial resolution. As spatial resolution is improved, there is a growing demand for developing more accurate and convenient guide systems. Therefore, in the present study, we have developed and prototyped a 3D printed wearable subject-specific helmet for LIFU stimulation that is guaranteed to be accurate. The spatial relationship between the target position and the full-width at half-maximum (FWHM) of acoustic pressure of the transducer, i.e. focal volume, was compared using the conventional image-guided navigation system. According to the distribution of positional errors, the target position was located well within the focal volume.
More Related Videos
09:03Disruption of the Blood-Spinal Cord Barrier Using Low-Intensity Focused Ultrasound in a Rat Model
Published on: March 10, 2023
08:02A High-Throughput Image-Guided Stereotactic Neuronavigation and Focused Ultrasound System for Blood-Brain Barrier Opening in Rodents
Published on: July 16, 2020
Related Concept Videos
Sound Intensity
Sound Intensity Level
The human ear can perceive an extensive range of sound intensity, necessitating the use of the logarithmic scale to define a physical quantity—the intensity level. It is a ratio of two intensities and...
Cable Subjected to Its Own Weight
A generalized loading function is employed to analyze a cable subjected to its own weight. This function considers the force acting along the cable's arc length rather than its projected length, providing a more accurate...
Intensity Of Electromagnetic Waves
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Assessment of the Gastrointestinal System I: Subjective Data
Health History
The initial step in assessing the GI system is obtaining a comprehensive health history. This includes inquiring about the patient's history or presence of problems...