Comprehensive comparison of ambient mass spectrometry with desorption electrospray ionization and direct analysis in

Lei Li1, Qiqin Wang2, Wen Li3

  • 1Institute of Mass Spectrometer and Atmospheric Environment, Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air Pollution, Jinan University, Guangzhou, 510632, China.

Talanta
|June 17, 2019
PubMed

Related Concept Videos

Electrospray Ionization (ESI) Mass Spectrometry01:12

Electrospray Ionization (ESI) Mass Spectrometry

Higher molecular weight biomolecules are nonvolatile compounds that may decompose before ionizing or vaporizing during mass analysis with conventional electron impact ionization methods. Accordingly, electrospray ionization (ESI) is the favored method for vaporizing and ionizing biomolecules as it circumvents rapid fragmentation and enables the recording of mass signals for the entire biomolecule.
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
2.2K
Chemical Ionization (CI) Mass Spectrometry01:21

Chemical Ionization (CI) Mass Spectrometry

The molecular ion peak of a molecule in the mass spectrum provides vital information for molecular identification. However, conventional electron impact ionization can lead to the rapid dissociation of some molecular ions before they reach the detector. A milder ionization method is required to increase the lifetime of such ionized analyte molecules. Chemical ionization (CI) is a gas-phase protonation reaction useful for mass-analyzing analyte molecules that are easily protonated to yield the...
1.5K
Mass Spectrometry: Complex Analysis01:21

Mass Spectrometry: Complex Analysis

Mass spectrometry is an important technique for the identification of pure compounds. However, it has some limitations for the analysis of complex mixtures, often due to excessive fragmentation making the spectrum too complicated to decipher. Mass spectrometry can be combined with suitable separation methods in sequence, forming hyphenated methods, which are useful in the analysis of complex mixtures.
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
1.7K
Directing Effect of Substituents: meta-Directing Groups01:09

Directing Effect of Substituents: meta-Directing Groups

Substituents on the benzene ring that direct an incoming electrophile to undergo substitution at the meta position are called meta directors. All meta directors either have a positive charge on the atom directly bonded to the ring or a partial positive charge. These groups function by withdrawing electrons from the ring through inductive and resonance effects. Consider the carbocation intermediates formed upon the addition of an electrophile on nitrobenzene at the...
5.8K
Matrix-Assisted Laser Desorption Ionization (MALDI)01:08

Matrix-Assisted Laser Desorption Ionization (MALDI)

Matrix-assisted laser desorption ionization (MALDI) is a powerful analytical technique used in mass spectrometry. It enables the identification and characterization of various biomolecules, including proteins, peptides, nucleic acids, and carbohydrates. MALDI is an ionization technique, widely employed in biological and medical research, as well as in fields like pharmacology and biochemistry.The analyte of interest, a biomolecule or a mixture of biomolecules, is mixed with a suitable matrix...
1.0K
Directing Effect of Substituents: ortho–para-Directing Groups01:14

Directing Effect of Substituents: ortho–para-Directing Groups

Ortho–para directors are substituent groups attached to the benzene ring and direct the addition of an electrophile to the positions ortho or para to the substituent. All electron-donating groups are considered ortho–para directors. They donate electrons to the ring and make the ring more electron-rich. The ring is therefore susceptible to the addition of electrophiles. Substituents such as amino, hydroxy, or alkoxy, containing lone pairs on the atom adjacent to the ring, donate...
8.3K