Related Experiment Video
Updated: Jan 23, 2026

2-Methacryloyloxyethyl Phosphorylcholine Polymer Treatment of Complete Dentures to Inhibit Denture Plaque Deposition
Published on: December 26, 2016
Comparison of nonscheduled, postinsertion adjustment visits for complete dentures fabricated with conventional and
Carl Drago1, Andrew J Borgert2
1Prosthodontist, Gundersen Health System, LaCrosse, Wis; Adjunct Associate Professor, Graduate Prosthodontics, Marquette University School of Dentistry, Milwaukee, Wis.
Statement Of Problem:
Unscheduled denture-adjustment visits may disrupt both patients and clinicians. Denture-adjustment visits have not been correlated with denture-processing methods.
Purpose:
The purpose of this clinical study was to identify differences in the number of unscheduled postinsertion-adjustment visits of patients with complete dentures fabricated by injection molding (IM) versus dentures fabricated by computer-aided design and computer-aided manufacturing (CAD-CAM).
Material And Methods:
One hundred six participants were evaluated in the study. They were consecutively treated in a private practice setting and followed up for 1 year after the insertion of new complete dentures. The first 33 received dentures fabricated using an IM system, and the other 73 were milled using a CAD-CAM system. All participants had been edentulous for at least 1 year. Participant ages ranged from 29 to 83 years. IM dentures were fabricated by a commercial dental laboratory; CAD-CAM dentures were milled by a commercial manufacturer. All participants were scheduled for 1- or 2-week postinsertion office visits. Further adjustment visits were scheduled according to participant request. The results were tabulated, and univariable tests of association were performed including chi-square and the Fisher exact tests for categorical comparisons and the Wilcoxon rank sum test for comparison of ordinal continuous data. A multivariable logistic regression model was used to control for the influence of multiple predictor variables on the outcome of interest.
Results:
Edentulous years ranged from 1 to 60. Approximately one half (n=56) of all participants returned for scheduled postinsertion visits approximately 1 to 2 weeks after insertion of the dentures. No significant demographic or clinical differences were noted between participants receiving CAD-CAM or conventional dentures. Return visits for unscheduled adjustments were not associated with the method of denture fabrication or any other demographic features (P=.55).
Conclusions:
Based on the results of this study, there were no significant differences in the number of unscheduled, postinsertion visits for participants whose dentures were fabricated following IM or CAD-CAM milling protocols. Clinicians may choose to fabricate complete dentures with either protocol and expect similar clinical results in terms of the number of unscheduled postinsertion visits.
Related Concept Videos
C4 Pathway and CAM
C4 Pathway
The C4 pathway is used by plants such as...
Adjusting a Traverse
The Anchoring-and-Adjustment Heuristic
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Sign Convention
The normal force acts perpendicular to the beam's cross-section and can...
Aneurysm II: Clinical Manifestations and Diagnostic Studies

