Application of Low Tube Potentials in CCTA: Results From the PROTECTION VI Study
Thomas J Stocker1, Jonathon Leipsic2, Martin Hadamitzky3
1Medizinische Klinik und Poliklinik I, Ludwig Maximilians-Universität, Munich, Germany; DZHK (German Center for Cardiovascular Research), Partner Site Munich Heart Alliance, Munich, Germany.
Objectives:
The aim of this study was to assess the use of low tube potentials for coronary computed tomography angiography (CCTA) in worldwide clinical practice and its influence on radiation exposure, contrast agent volume, and image quality.
Background:
CCTA is frequently used in clinical practice. Lowering of tube potential is a potent method to reduce radiation exposure and to economize contrast agent volume.
Methods:
CCTAs of 4,006 patients from 61 international study sites were analyzed regarding very-low (≤80 kVp), low (90 to 100 kVp), conventional (110 to 120 kVp), and high (≥130 kVp) tube potentials. The impact on dose-length product (DLP) and contrast agent volume was analyzed. Image quality was determined by evaluation of the diagnostic applicability and assessment of the objective image parameters signal-to-noise-ratio (SNR) and contrast-to-noise-ratio (CNR).
Results:
When compared with conventional tube potentials, low tube potentials were used in 56% of CCTAs (≤80 kVp: 9%; 90 to 100 kVp: 47%), which varied among sites from 0% to 100%. Tube potential reduction was associated with low-cardiovascular risk profile, low body mass index (BMI), and new-generation scanners. Median radiation exposure was lowered by 68% or 50% and median contrast agent volume by 25% or 13% for tube potential protocols of ≤80 kVp or 90 to 100 kVp when compared with conventional tube potentials, respectively (all p < 0.001). With the use of lower tube potentials, the frequency of diagnostic scans was maintained (p = 0.41), whereas SNR and CNR significantly improved (both p < 0.001). Considering BMI eligibility criteria, 58% (n = 946) of conventionally scanned patients would have been suitable for low tube potential protocols, and 44% (n = 831) of patients scanned with 90 to 100 kVp would have been eligible for very-low tube potential CCTA imaging of ≤80 kVp.
Conclusions:
This large international registry confirms the feasibility of tube potential reduction in clinical practice leading to lower radiation exposure and lower contrast volumes. The current registry also demonstrates that this strategy is still underused in daily practice. (PROspective multicenter registry on radiaTion dose Estimates of cardiac CT angIOgraphy iN daily practice in 2017 [PROTECTION-VI]; NCT02996903).
Related Concept Videos
Zones of Protection
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Protection of Alcohols
Protection
It defines a protecting group as the masking agent to make the more reactive species inert to a given set of conditions. This concept is depicted via the illustration of liquid flow through different outlets in an assembly of pipes. The analogy helps to understand the role...
Protecting Self-Esteem
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Uterine Tubes
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....