Related Experiment Video
Updated: Jan 23, 2026

Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Practical Dose Parameter Values for the Prediction of the Adverse Effect of Neurointerventional Radiation:
Dae Han Choi1, Chan Jong Yoo1, Cheol Wan Park1
1Department of Neurosurgery, Gil Medical Center, Gachon University College of Medicine, Incheon, Republic of Korea.
Objective:
To present values for the dose parameters predictive of alopecia as an adverse effect induced by neuroembolization using a biplane fluoroscopy.
Methods:
This study included a total of 151 patients (52 men, mean age of 55.1 ± 12.2 years) treated for intracranial neuroembolization between 2014 to 2018 with the following criteria: 1) obtainable dose report with digital subtraction angiographic image records, 2) no history of radiation exposure 6 months prior to the first procedure, and 3) and clinical follow-up performed through 12 months following the procedure. Patients were divided into 2 groups according to their presentation of alopecia during the follow-up period.
Results:
Eighteen (11.9%) patients developed alopecia 10 to 30 days after the procedure (average: 18.5 ± 5.3 days). Sixteen (88.9%) patients in the alopecia group were affected by projection of the A-plane fluoroscopy. Area under the receiver operating characteristic analysis curves of 0.865 (P = 0.000) and 0.831 (P = 0.000) were used to compute the optimal A-plane dose area product (255.4 Gy-cm2; sensitivity: 0.875; specificity: 0.805; Youden J = 0.682) and cumulative dose (4437.5 mGy; sensitivity, 0.750; specificity, 0.805; Youden J = 0.556) cutoff values, respectively, capable of distinguishing patients with alopecia (n = 16) from subtotal patients (n = 149).
Conclusions:
The dose area product and the cumulative dose may be useful, intuitive factors for predicting the adverse effects of the neurointerventional radiation. Further multicenter research should be performed to confirm the efficacy and utility of the reference values of dose area product and cumulative dose for preventing excessive irradiation during neurointerventional procedures.
More Related Videos
Related Concept Videos
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations
Dose-Response Relationship: Overview
Insulin: Dosing Regimen and Adverse Effects
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...
Dose-Response Relationship: Potency and Efficacy
Dose-Response Relationship: Selectivity and Specificity