Related Experiment Video
Updated: Jan 23, 2026

Reduced Itraconazole Concentration and Durations Are Successful in Treating Batrachochytrium dendrobatidis Infection in Amphibians
Published on: March 14, 2014
An interpretation to Cr(Ⅵ) leaching concentration rebound phenomenon with time in ferrous-reduced Cr(Ⅵ)-bearing solid
Dong Li1, Chenxin Gui2, Guozhu Ji2
1State Key Laboratory of Coal Mine Disaster Dynamics and Control, Chongqing University, Chongqing, 400044, PR China; School of Resources and Environmental Science, Chongqing University, Chongqing, 400044, PR China; Key Laboratory of Southwest Resources Exploitation and Environmental Hazards Controlling Engineering of Education Ministry, Chongqing University, Chongqing, 400030, PR China.
Abstract:
Toxicity characteristic leaching procedure (TCLP) is a prevalent way to evaluate the treatment effectiveness for Cr(Ⅵ)-bearing solid matrices (CBSM). But when a certain amount of residual reductants are present in the treated CBSM, Cr(Ⅵ) leaching concentration rebound phenomenon (CLCRP) occurs, which invalidates the TCLP. This study explores the microstructure of ferrous-reduced CBSM and proves that the residual Cr(Ⅵ), FexCr1-x(OH)3 precipitate and residual ferrous are separately distributed in a three-layer structure. In natural scenarios, the residual ferrous in the out-layer is firstly flushed away by rainfall and groundwater or oxidized by dissolved oxygen, resulting in the decrease of ferrous with time. Residual Cr(Ⅵ), due to being blocked by precipitate layer, is less flushed away. While in TCLP, all of released residual ferrous and Cr(Ⅵ) are in the leachate and react till one of them is almost exhausted, resulting in the underestimation of Cr(Ⅵ) leaching concentrations. The longer the samples experience the natural scenarios, the less of the residual ferrous, resulting in the decline of underestimation of Cr(Ⅵ) leaching concentrations with time. This study also provides a pretreatment which can effectively reduce the residual ferrous, achieving more accurate Cr(Ⅵ) leaching concentrations and eliminating CLCRP.
Related Concept Videos
Tip-of-the-Tongue Phenomenon
Time-Domain Interpretation of PD Control
Consider the example of control of motor torque. Initially, a positive...
Drug Concentration Versus Time Correlation
Two pivotal parameters are the minimum effective concentration (MEC) and the minimum toxic concentration (MTC). The MEC is the...
The Integrated Rate Law: The Dependence of Concentration on Time
Time and frequency -Domain Interpretation of PI Control
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...

