Related Experiment Video
Updated: Jan 23, 2026

Contrast Enhanced Vessel Imaging using MicroCT
Published on: January 27, 2011
Added Value of Contrast Medium in Whole-Body Hybrid Positron Emission Tomography/Magnetic Resonance Imaging:
Filiz Celebi1, Emetullah Cindil2, Dauren Sarsenov3
1Department of Radiology, Gayrettepe Florence Nightingale Hospital, Istanbul, Turkey, elbuken.filiz@gmail.com.
Objective:
To compare the diagnostic ability and time efficiency of contrast-enhanced (CE) whole body fluorodeoxyglucose (FDG) positron emission tomography/magnetic resonance imaging (PET/MRI) protocol and non-CE (NCE) protocol.
Subjects And Methods:
Ninety-three patients with known primary tumors underwent whole-body hybrid FDG PET/MRI during the follow-up of their malignancies with the use of NCE and CE protocols. The NCE PET/MRI protocol consisted of diffusion-weighted (b = 0 and 800 s/mm2) and T1-weighted Turbo Flash in the axial plane and T2-weighted HASTE sequence in the coronal planes (Σ = 25 min). The CE PET/MRI protocol was performed by acquiring axial serial CE 3D FS VIBE images in the upper abdomen, completing the whole body in the late phase in the axial plane (Σ = 30 min).
Results:
There was a statistically significant difference between the total number of lesions detected by the CE protocol (median 2, interquartile range (IQR) 0-14) and that detected by the NCE protocol (median 1, IQR 0-5; p < 0.001). More malignancies were detected in the abdomen (p < 0.001) and brain (p < 0.001) with the CE PET/MRI protocol, whereas no significant difference was present when comparing the 2 protocols in the detection of malignancies in the head and neck (p = 0.356), thorax (p = 0.09), lymph nodes (p = 0.196), and bone (p = 0.414).
Conclusion:
The CE FDG PET/MRI protocol enables fast and accurate detection of malignancies compared to the NCE FDG PET/MRI protocol, particularly in the upper abdomen and brain. Diagnostic ability and time efficiency can be increased with the proposed short CE protocol in place of the whole body PET/MRI protocol including both NCE and CE imaging sequences.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Magnetic Resonance Imaging
Self-Evaluation: Self-Enhancement and Self-Verification
Bioavailability Enhancement: Drug Solubility Enhancement