Related Experiment Video
Updated: Jan 23, 2026

MRI and PET in Mouse Models of Myocardial Infarction
Published on: December 19, 2013
Differentiation of treatment-related changes from tumour progression: a direct comparison between dynamic FET PET and
Jan-Michael Werner1, Gabriele Stoffels2, Thorsten Lichtenstein3
1Department of Neurology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.
Background:
Following brain cancer treatment, the capacity of anatomical MRI to differentiate neoplastic tissue from treatment-related changes (e.g., pseudoprogression) is limited. This study compared apparent diffusion coefficients (ADC) obtained by diffusion-weighted MRI (DWI) with static and dynamic parameters of O-(2-[18F]fluoroethyl)-L-tyrosine (FET) PET for the differentiation of treatment-related changes from tumour progression.
Patients And Methods:
Forty-eight pretreated high-grade glioma patients with anatomical MRI findings suspicious for progression (median time elapsed since last treatment was 16 weeks) were investigated using DWI and dynamic FET PET. Maximum and mean tumour-to-brain ratios (TBRmax, TBRmean) as well as dynamic parameters (time-to-peak and slope values) of FET uptake were calculated. For mean ADC calculation, regions-of-interest analyses were performed on ADC maps calculated from DWI coregistered with the contrast-enhanced MR image. Diagnoses were confirmed neuropathologically (21%) or clinicoradiologically. Diagnostic performance was evaluated using receiver-operating-characteristic analyses or Fisher's exact test for a combinational approach.
Results:
Ten of 48 patients had treatment-related changes (21%). The diagnostic performance of FET PET was significantly higher (threshold for both TBRmax and TBRmean, 1.95; accuracy, 83%; AUC, 0.89 ± 0.05; P < 0.001) than that of ADC values (threshold ADC, 1.09 × 10-3 mm2/s; accuracy, 69%; AUC, 0.73 ± 0.09; P = 0.13). The addition of static FET PET parameters to ADC values increased the latter's accuracy to 89%. The highest accuracy was achieved by combining static and dynamic FET PET parameters (93%). Moreover, in contrast to ADC values, TBRs <1.95 at suspected progression predicted a significantly longer survival (P = 0.01).
Conclusions:
Data suggest that static and dynamic FET PET provide valuable information concerning the differentiation of early treatment-related changes from tumour progression and outperform ADC measurement for this highly relevant clinical question.
Related Concept Videos
Biasing of FET
In an N-channel JFET, the structure consists of N-type material forming the channel on a P-type substrate, with the...
Biodiversity and Human Values
Professional Values
The values that are the foundation of the nursing profession are altruism, autonomy, human dignity, and social justice.
First, altruism refers to the concern for the welfare and well-being of others without personal...
Critical Values
z Scores and Unusual Values
This score indicates how far a value is from the mean in terms of standard deviation. For example, if a data value has a z score of +1, the researcher can infer that the particular data value is one standard deviation above the mean. If another data...
Absolute and Local Extreme Values

![Quantitative [18F]-Naf-PET-MRI Analysis for the Evaluation of Dynamic Bone Turnover in a Patient with Facetogenic Low Back Pain](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F58491.jpg&w=3840&q=50)