Related Experiment Video
Updated: Jan 23, 2026

A Murine Tail Lymphedema Model
Published on: February 10, 2021
Perioperative variations in indices derived from noninvasive assessments to detect postmastectomy lymphedema
Kotaro Suehiro1, Shigeru Yamamoto2, Saiko Honda3
1Department of Surgery and Clinical Science, Yamaguchi University Graduate School of Medicine, Ube, Yamaguchi, Japan.
Objective:
This study aimed to clarify the variations in indices derived from noninvasive assessments for the early detection of postmastectomy lymphedema (LE) from 1 month preoperatively until 2 years postoperatively.
Methods:
In total, 120 patients who underwent surgery for breast cancer in our institution were prospectively followed up with a questionnaire for arm swelling as well as with tape measurements, bioimpedance analysis (BIA), and skin and subcutaneous tissue ultrasound at 1 month before and 3, 6, 12, 18, and 24 months after surgery.
Results:
Ninety-seven patients completed the study. Among 93 patients who did not present with LE, 9% complained of arm swelling even before surgery, and the incidence peaked at 17% at 6 months after surgery. There were no differences in the circumferences of the upper arm, forearm, and hand between sides throughout the study period. However, the postoperative circumference values of the upper arm only on the operation side were slightly increased compared with the preoperative values. The mean excess fluid in the arm on the operation side compared with the contralateral side, as assessed by BIA, was nearly zero throughout the study period. There were no differences in subcutaneous echogenicity or skin and subcutaneous thicknesses between the sides throughout the study period. However, time-dependent increases in subcutaneous thicknesses were noticed on both sides. Four patients (4.1%) developed LE. In three of these patients, abnormality in the BIA was recorded 6 to 12 months before presentation. Immediately after presentation, the common findings included BIA abnormality and increased subcutaneous echogenicity and skin thickness in the medial forearm.
Conclusions:
In this study, a complaint of arm swelling was not sensitive enough for detection of the early onset of LE because a certain number of patients constantly complained of this symptom. Measurements of circumference might help in the diagnosis of LE onset, but this method is not specific enough because these measurements are also affected by various factors. However, BIA and skin and subcutaneous ultrasound were identified as potential tools for the early detection of LE.
Related Concept Videos
Indicators
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
What is Variation?
The range, standard deviation, standard error, and variance are the different measures of variation.
Range: The range is the difference between its maximum and...
Variation
When independent and dependent variables are plotted on a scatter plot, the slope of a line is a value that describes the rate of change between the two...
Variation: Normal Distribution, Range, and Standard Deviation
Conservative Site-specific Recombination and Phase Variation
The recognition sites for Cre recombinase called LoxP...

