Related Experiment Video
Updated: Jan 23, 2026

Phthalic Acid Ester-Binding DNA Aptamer Selection, Characterization, and Application to an Electrochemical Aptasensor
Published on: March 21, 2018
Electrochemical aptamer-based microsensor for real-time monitoring of adenosine in vivo
Di Zhang1, Jiajia Ma2, Xiangwen Meng2
1Binhai Industrial Technology Research Institute of Zhejiang University, Tianjin, 300301, PR China.
Abstract:
In this work, an implantable and minimally invasive micro-aptasensor for adenosine monitoring in vivo, based on flexible integrated electrodes, was developed. Firstly the sensor was made by the modification of a needle-type electrode with reduced graphene oxide and gold nanoclusters (rGO-AuNCs) using two-step electrodeposition. Secondly Sulfhydryl-terminated capture probe (ssDNA1) was immobilized on rGO-AuNCs modified electrode surface by self-assembly, and then it was hybridized with adenosine aptamer (ssDNA2). Lastly methylene blue (MB) as an electrochemical indicator was adsorbed on the aptamer through specific interaction of MB with guanine base. The peak current of MB decreased linearly with increasing adenosine concentration due to the formation of aptamer-adenosine complex and displacement of the aptamer from the modified electrode surface. The sensor showed a low detection limit of 0.1 nM with signal-to-noise ratio equal to 3 as well as a wide linear response range (0.1 nM-1 mM) in vitro. Also, a high selectivity was demonstrated for adenosine in relation to uridine, guanosine, and cytidine. Experiments in vivo demonstrated fast responses for a range of adenosine concentrations. This work demonstrates a promising path for implantable devices for the determination of biomolecules in vivo, thus allowing for health tests, detection of infectious diseases, and other medical conditions.
Related Concept Videos
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
Real Time RT-PCR
The real-time quantification of the number of amplified products is...
Interfacial Electrochemical Methods: Overview
Electrochemical Gradient and Channel Proteins: An Overview
The electrical gradient: The electrical gradient across cell membranes refers to the difference in electric charge between the inside and outside of a cell. This difference drives the movement of ions towards or away from the cells. For instance, if the inside of the cell is more negatively charged relative to...
Self-Presentation: Self-Monitoring and Self-Handicapping
Holter Monitor: 24-Hour Monitoring

