Related Experiment Video
Updated: Jan 23, 2026

Murine Model of Leukemia Relapse to Induction Chemotherapy for Acute Lymphoblastic Leukemia
Published on: October 17, 2025
Elastic modulus and migration capability of drug treated leukemia cells K562
Kui Wang1, Yuntian Xue2, Ying Peng2
1Department of Biomedical Engineering, Southern University of Science and Technology, Shenzhen, 518055, PR China; Department of Mechanical Engineering, University of Hong Kong, Hong Kong, PR China.
Abstract:
Leukemia is a commonly seen disease caused by abnormal differentiation of hematopoietic stem cells and blasting in bone marrow. Despite drugs are used to treat the disease clinically, the influence of these drugs on leukemia cells' biomechanical properties, which are closely related to complications like leukostasis or infiltration, is still unclear. Due to non-adherent and viscoelastic nature of leukemia cells, accurate measurement of their elastic modulus is still a challenging issue. In this study, we adopted rate-jump method together with optical tweezers indentation to accurately measure elastic modulus of leukemia cells K562 after phorbol 12-myristate 13-acetate (PMA), all-trans retinoic acid (ATRA), Cytoxan (CTX), and Dexamethasone (DEX) treatment, respectively. We found that compared to control sample, K562 cells treated by PMA showed nearly a threefold increase in elastic modulus. Transwell experiment results suggested that the K562 cells treated with PMA have the lowest migration capability. Besides, it was shown that the cytoskeleton protein gene α-tubulin and vimentin have a significant increase in expression after PMA treatment by qPCR. The results indicate that PMA has a significant influence on protein expression, stiffness, and migration ability of the leukemia cell K562, and may also play an important role in the leukostasis in leukemia.
Related Concept Videos
Strain and Elastic Modulus
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by a...
Bulk Modulus
Fineness Modulus
Consider performing sieve analysis on sand through a set of ASTM sieves. The weight of aggregate retained in each sieve and pan placed at the bottom is recorded, as given in Column B of Table 1.
To determine the fineness modulus of...
Cell Migration

