Evaluation of saline versus gel as contact medium for ultrasonographic image quality
George W Williams1, Chunyan Cai2, Carlos A Artime1
1McGovern Medical School at UTHealth, Houston, Texas.
Objectives:
Evaluate the time taken to visualize the internal jugular vein and carotid arteries, and subjective image quality assessed on a 0-100 visual analogic scale, on an ultrasound model using either traditional ultrasound gel or normal saline.
Methods:
Twenty-two anesthesiology residents and twenty anesthesiology faculty were blinded and randomized into four separate groups using gel and saline as a conduction medium, in different sequences.
Results:
Subjective image quality was 12.2 ± 4.2 better with gel than with saline (P < 0.01). Image acquisition time did not differ significantly between the two mediums. There was no significant difference in subjective image quality or time to image acquisition between faculty and residents.
Conclusions:
Internal jugular vein and carotid artery identification time using ultrasonography were similar between gel and saline as conduction mediums. The difference in subjective image quality did not appear clinically relevant. Better image quality resulted in less time taken to identify the structures, as expected. We conclude that saline may be an effective alternative medium to gel for vessel imaging and access guidance. Further study in a clinical setting is warranted.
Related Concept Videos
Contact-dependent Signaling
Gap Junctions
In animal cells, gap junctions are formed...
Contact Angle
The adhesive force is the molecular force between molecules of different materials, that is, between the molecules of the solid and the liquid. The cohesive...
Quality of Water
Quality Control
Quality control helps track data, visualize trends, and identify variations, making it easier to detect deviations that may affect the accuracy of an analysis. One way to do this is by generating a quality control chart, which...
Quality Assurance
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...