Purpose:
The purpose of this study is to characterize the magnitude and depth of dose buildup in pencil beam scanning proton therapy.
Methods:
We simulate the integrated depth-dose curve of realistic proton pencil beams in a water phantom using the Geant4 Monte Carlo toolkit. We independently characterize the electronic and protonic components of dose buildup as a function of proton beam energy from 40 to 400 MeV, both with and without an air gap.
Results:
At clinical energies, electronic buildup over a distance of about 1 mm leads to a dose reduction at depth of the basal layer (0.07 mm) by up to 6% compared to if no buildup effect were present. Protonic buildup reduces the dose to the basal layer by up to 16% and has effects at depths of up to 150 mm. Secondary particles with a mass number A > 1 do not contribute to dose buildup. An air gap of 1 m has no significant effect on protonic buildup but reduces electronic buildup below 1%.
Conclusions:
Protonic and electronic dose buildup are relevant for accurate dosimetry in proton therapy although a realistic air gap reduces the electronic buildup to levels where it can be safely neglected. We recommend including electrons and secondary protons in Monte Carlo-based treatment planning systems down to a predicted range of 10-20 μ m in order to accurately model the dose at depths of the basal layer, no matter the size of the air gap between nozzle and patient.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
05:54Stereo-Electro-Encephalo-Graphy SEEG With Robotic Assistance in the Presurgical Evaluation of Medical Refractory Epilepsy: A Technical Note
Published on: June 13, 2016
Related Concept Videos
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Dose Size and Dosing Frequency: Determination Methods
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses
Deflection of a Beam
Singularity functions, described in an earlier lesson, are powerful mathematical tools that represent discontinuities within a function commonly encountered in structural loading...
Rational Dosage Regimen: Maintenance Dose and Loading Dose
In most cases, drugs are administered repetitively or infused continuously to maintain a steady-state concentration in the body. At a steady...
Proton (¹H) NMR: Chemical Shift
Absorption signals of all the protium nuclei...