Feasibility of Virtual Reality Combined with Isocentric Navigation in Transforaminal Percutaneous Endoscopic
Zhi Zhou1,2, Shuo Hu1, Yong-Zhao Zhao1
1Orthopaedics Department, Shanghai Tenth People's Hospital, Shanghai, China.
Objectives:
Transforaminal percutaneous endoscopic discectomy (TPED) is one of the most commonly used minimally invasive spine surgeries around the world. However, conventional surgical planning and intraoperative procedures for TPED have relied on surgeons' experience, which limits its standardization and popularization. Virtual reality (VR) is a novel technology for pre-surgical planning in various fields of medicine, while isocentric navigation can guide intraoperative procedures for TPED. The present study aimed to explore the feasibility of applying VR combined with isocentric navigation in TPED on cadavers.
Methods:
The surgical levels were L3 /L4 and L4 /L5 as well as L5 /S1 of both sides of each cadaver specimen. First, the surgeon manually conducted the above procedures on the left side of every specimen without preoperative simulation and isocentric navigation (Group A). Then the same surgeon conducted the VR simulation for surgical planning of the right side (Group B). After VR simulation, the same surgeon made the percutaneous punctures and placed the working channel on the right side of the specimen at all levels.
Results:
At the L3 /L4 level, the puncture-channel time was 11.36 ± 2.13 min in Group A and 11.29 ± 2.23 min in Group B (t = 0.097, P = 0.938). The exposure time was 17.21 ± 2.91 s in Group A and 14.64 ± 1.60 s in Group B (t = 2.534, P = 0.025). At the L4 /L5 level, the puncture-channel time was 13.86 ± 3.90 min in Group A and 11.93 ± 2.95 min in Group B (t = 2.291, P = 0.039). Exposure time was 20.64 ± 3.84 s in Group A and 16.43 ± 2.47 s in Group B (t = 6.118, P < 0.01). There were 7 patients undergoing foraminotomy in Group A and 3 patients undergoing foraminotomy in Group B (t = 2.280, P = 0.236). At the L5 /S1 level, the puncture-channel time was 18.21 ± 1.85 min in Group A and 15.71 ± 3.20 min in Group B (t = 2.476, P = 0.028). Exposure time was 26.07 ± 3.17 s in Group A and 22.50 ± 2.68 s in Group B (t = 2.980, P = 0.011). There were 14 patients receiving foraminotomy in Group A and 13 patients receiving foraminotomy in Group B (t = 1.000, P = 1.000).
Conclusions:
Virtual reality combined with isocentric navigation is feasible in TPED. It enables precise surgical planning and improves intraoperative procedures, and has the potential for application in clinical practice.
Related Concept Videos
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Virtual Work
In static equilibrium, a body can experience an imaginary or virtual movement, such as displacement or rotation. The virtual work done by a force is equal to the dot product of force and virtual displacement in the direction of the force. When it comes to virtually rotating a...
Principle of Virtual Work: Problem Solving
To apply the principle of virtual work,...
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:


