Related Experiment Video
Updated: Jan 23, 2026

Phase Contrast Magnetic Resonance Imaging in the Rat Common Carotid Artery
Published on: September 5, 2018
Hypervascular hepatic focal lesions on dynamic contrast-enhanced CT: preliminary data from arterial phase scans
1Department of Radiology, Xuanwu Hospital, Capital Medical University, Beijing, China; Department of Radiology, The Affiliated Hospital of Qingdao University, Qingdao, China; Beijing Key Laboratory of Magnetic Resonance Imaging and Brain Informatics, Beijing, China.
Aim:
To investigate the ability of computed tomography texture analysis (CTTA) to distinguish different hypervascular hepatic focal lesions.
Materials And Methods:
CTTA software was used to analyse retrospectively 18 cases of focal nodular hyperplasia, 10 cases of hepatic adenoma, 20 cases of haemangioma, 20 cases of hepatocellular carcinoma, and 20 cases of hepatic metastases using arterial phase scans. A list of texture features was generated for lesion classification. Fisher's discriminant analysis (FDA) was used to construct a predictive model from these parameters and to estimate the discriminant accuracy. Receiver operating characteristic (ROC) curve analysis was used to assess the diagnostic performance of texture analysis of benign and malignant tumours.
Results:
Fifteen texture features were significant differences between the five different histopathological types of all lesions. The total discriminant accuracy was 69.3%, with 55.7% cross-validation accuracy. Seven texture features showed significant differences between the benign and malignant tumours. The total discriminant accuracy in the sample was 83%, with 77.3% cross-validation accuracy. The area under the ROC curve (AUROC) of united texture features was 0.927 (95% confidence interval [CI]=0.875-0.979).
Conclusions:
CTTA can be used as an aid in the differential diagnosis of hypervascular solid focal hepatic lesions, especially the differential diagnosis between benign and malignant lesions.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Shape and Texture of Coarse Aggregate
Leaky Scanning
Phase Transitions
Analysis of Population Pharmacokinetic Data
Classification of Titrimetric Analysis Based on Reaction Types
Titrations between an acid and a base lead to neutralization reactions that form...