Related Experiment Video
Updated: Jan 23, 2026

A Multicenter MRI Protocol for the Evaluation and Quantification of Deep Vein Thrombosis
Published on: June 2, 2015
Interobserver reproducibility of tumor uptake quantification with 89Zr-immuno-PET: a multicenter analysis
Yvonne W S Jauw1,2, Frederike Bensch3, Adrienne H Brouwers4
1Department of Hematology, Cancer Center Amsterdam, Amsterdam UMC, Vrije Universiteit Amsterdam, De Boelelaan 1117, 1081 HV, Amsterdam, The Netherlands. yws.jauw@amsterdamumc.nl.
Interobserver reproducibility of tumor uptake quantification using 89-zirconium (89Zr)-immuno-PET scans was excellent for SUVmax and SUVpeak with manual segmentation. Semi-automatic methods showed limited robustness due to low tumor contrast.
Area of Science:
- Nuclear Medicine
- Radiopharmaceuticals
- Oncology Imaging
Background:
- 89-zirconium (89Zr)-labeled monoclonal antibodies (mAbs) with PET enable in-vivo tumor uptake quantification.
- Optimizing tumor targeting and therapeutic efficacy is a key goal.
- Low tumor contrast in 89Zr-immuno-PET poses challenges for accurate delineation and can lead to interobserver variation.
Purpose of the Study:
- To assess the interobserver reproducibility of tumor uptake measurements derived from 89Zr-immuno-PET scans.
- To evaluate the reliability of manual tumor delineation for quantitative analysis.
- To compare manual and semi-automatic methods for volume of interest (VOI) delineation.
Main Methods:
- Retrospective analysis of clinical data using 89Zr-rituximab, 89Zr-cetuximab, and 89Zr-trastuzumab.
- Manual delineation of tumor volumes of interest (VOIs) by three independent observers.
- Quantification of tumor uptake using maximum, peak, and mean standardized uptake values (SUVmax, SUVpeak, SUVmean).
- Calculation of interobserver variability using the coefficient of variation (CoV).
- Evaluation of a semi-automatic delineation method based on background-corrected ACpeak.
Main Results:
- A total of 103 VOIs were delineated 3-6 days post-injection.
- Excellent interobserver reproducibility was observed for SUVmax (0% CoV) and SUVpeak (0% CoV).
- SUVmean showed moderate interobserver variability (7% CoV).
- The semi-automatic delineation method achieved a success rate of only 45%, primarily failing due to background inclusion.
Conclusions:
- Standardized manual tumor segmentation on 89Zr-immuno-PET provides excellent interobserver reproducibility for SUVmax and SUVpeak.
- Semi-automatic delineation is not yet robust for quantitative analysis due to challenges with low tumor contrast.
- Manual delineation remains a reliable method for quantitative tumor uptake assessment in 89Zr-immuno-PET studies.
Related Concept Videos
Drugs Affecting Neurotransmitter Release or Uptake
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Tumor Immunotherapy
Agonism and Antagonism: Quantification
To quantify these effects, researchers use a dose-response curve, which provides valuable information about the potency and efficacy of a drug. Potency refers to...
Tumor Progression
Colon cancer is one of the best-documented examples of tumor progression. Early mutation in the APC gene in colon cells causes a small growth on the colon wall called a polyp. With time, this polyp grows into a benign, pre-cancerous tumor. Further...
The Tumor Microenvironment