Prospective acceleration of parallel RF transmission-based 3D chemical exchange saturation transfer imaging with
Hye-Young Heo1,2, Xiang Xu1,2, Shanshan Jiang1
1Divison of MR Research, Department of Radiology, Johns Hopkins University, Baltimore, Maryland.
Purpose:
To develop prospectively accelerated 3D CEST imaging using compressed sensing (CS), combined with a saturation scheme based on time-interleaved parallel transmission.
Methods:
A variable density pseudo-random sampling pattern with a centric elliptical k-space ordering was used for CS acceleration in 3D. Retrospective CS studies were performed with CEST phantoms to test the reconstruction scheme. Prospectively CS-accelerated 3D-CEST images were acquired in 10 healthy volunteers and 6 brain tumor patients with an acceleration factor (RCS ) of 4 and compared with conventional SENSE reconstructed images. Amide proton transfer weighted (APTw) signals under varied RF saturation powers were compared with varied acceleration factors.
Results:
The APTw signals obtained from the CS with acceleration factor of 4 were well-preserved as compared with the reference image (SENSE R = 2) both in retrospective phantom and prospective healthy volunteer studies. In the patient study, the APTw signals were significantly higher in the tumor region (gadolinium [Gd]-enhancing tumor core) than in the normal tissue (p < .001). There was no significant APTw difference between the CS-accelerated images and the reference image. The scan time of CS-accelerated 3D APTw imaging was dramatically reduced to 2:10 minutes (in-plane spatial resolution of 1.8 1.8 mm2 ; 15 slices with 4-mm slice thickness) as compared with SENSE (4:07 minutes).
Conclusion:
Compressed sensing acceleration was successfully extended to 3D-CEST imaging without compromising CEST image quality and quantification. The CS-based CEST imaging can easily be integrated into clinical protocols and would be beneficial for a wide range of applications.
Related Concept Videos
Tactile and Chemical Senses
Types of Chemical Reactions: Exchange and Reversible
A special kind of exchange reaction is the oxidation-reduction reaction, or the redox reaction. These reactions involve the transfer of electrons from one compound to another. The electrons in these reactions commonly come from hydrogen atoms, which consist of an electron and a proton. A molecule gives up a...
Solution Equilibrium and Saturation
Energy Transfer in Chemical Reactions
Social Exchange Theory
The Sense of Self: Reflected Self-Appraisal and Social Comparison