Related Experiment Video
Updated: Jan 23, 2026

An Automated Method to Determine the Performance of Drosophila in Response to Temperature Changes in Space and Time
Published on: October 12, 2018
Performance and Reading Time of Automated Breast US with or without Computer-aided Detection
Shanling Yang1, Xican Gao1, Liwen Liu1
1From the Department of Ultrasonic Medicine, Xijing Hospital of the Fourth Military Medical University, No. 127 Changle West Road, Xi'an, Shaanxi, China 710032.
Abstract:
BackgroundComputer-aided detection (CAD) systems may be used to help radiologists interpret automated breast (AB) US images. However, the optimal use of CAD with AB US has, to the knowledge of the authors, not been determined.PurposeTo compare the performance and reading time of different readers by using AB US CAD system to detect breast cancer in different reading modes.Materials and MethodsIn this retrospective study, 1485 AB US images (282 with malignant lesions, 695 with benign lesions, and 508 healthy) in 1452 women (mean age, 43.7 years; age range, 19-82 years) including 529 (36.4%) women who were asymptomatic were collected between 2016 and 2017. A CAD system was used to interpret the images. Three novice readers with 1-3 years of US experience and three experienced readers with 5-10 years of US experience were assigned to read AB US images without CAD, at a second reading (after the reader completed a full unaided interpretation), and at concurrent reading (use of CAD at the start of the assessment). Diagnostic performances and reading times were compared by using analysis of variance.ResultsFor all readers, the mean area under the receiver operating characteristic curve improved from 0.88 (95% confidence interval [CI]: 0.85, 0.91) at without-CAD mode to 0.91 (95% CI: 0.89, 0.92; P < .001) at the second-reading mode and 0.90 (95% CI: 0.89, 0.92; P = .002) at the concurrent-reading mode. The mean sensitivity of novice readers in women who were asymptomatic improved from 67% (95% CI: 63%, 74%) at without-CAD mode to 88% (95% CI: 84%, 89%) at both the second-reading mode and the concurrent-reading mode (P = .003). Compared with the without-CAD and second-reading modes, the mean reading time per volume of concurrent reading was 16 seconds (95% CI: 11, 22; P < .001) and 27 seconds (95% CI: 21, 32; P < .001) shorter, respectively.ConclusionComputer-aided detection (CAD) was helpful for novice readers to improve cancer detection at automated breast US in women who were asymptomatic. CAD was more efficient when used concurrently for all readers.© RSNA, 2019Online supplemental material is available for this article.See also the editorial by Slanetz in this issue.
Related Concept Videos
Uncertainty in Measurement: Reading Instruments
Exercise and Muscle Performance
Endurance exercises
Endurance exercises involve running, swimming, or cycling, which require repetitive movements with low force output. When a person engages in endurance exercise, a few noticeable changes occur in their skeletal muscles. For instance, the number of capillaries...
Pathophysiology of Cardiac Performance
Distribution Reliability and Automation
Sources of Self-Esteem II: Performance Feedback
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:

