Computed Tomography for 4-Dimensional Angiography and Perfusion Imaging of the Prostate for Embolization Planning of
Adrian Kobe1, Gilbert Puippe1, Ernst Klotz2
1From the Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Zurich, Switzerland.
Objectives:
The aim of this study was to evaluate the feasibility of a computed tomography (CT) protocol enabling the visualization of the prostatic artery (PA) before prostatic artery embolization (PAE) in benign prostatic hyperplasia, which provides quantitative perfusion information of the prostate gland.
Materials And Methods:
In this institutional review board-approved study, 22 consecutive patients (mean age, 67 ± 7 years) who were planned to undergo PAE underwent a dynamic CT scan of the pelvis (scan range, 22.4 cm; cycle time, 1.5 seconds; scan time, 44 seconds; 25 scan cycles; 70 kVp; 100 mAs) after the administration of 70 mL of iodinated contrast media (flow rate, 6 mL/s; 10 seconds' delay). Image postprocessing consisted of a spatiotemporal, frequency-depending multiband filtering technique with noise reduction, motion correction, resulting in (1) time-resolved, temporal maximum intensity projection (MIP) images from fusion of multiple arterial time points; (2) 4-dimensional (4D) CT angiography images after bone and calcium plaque removal; and (3) parametric perfusion maps of the prostate. Intraprocedural cone-beam CT was performed with a microcatheter in the PA. In both modalities, the contrast-to-noise ratio of the right internal iliac artery or the PA was calculated, respectively. Visibility of the PA was scored using a Likert scale (score 1 = not seen, to score 4 = intraprostatic PA branches seen). Quantitative perfusion analysis of the dynamic pelvic CT included calculation of the blood flow, blood volume, mean transit time, and flow extraction product.
Results:
The average volume CT dose index and dose length product of CT was 35.7 ± 6.8 mGy and 737.4 ± 146.3 mGy·cm, respectively. Contrast-to-noise ratio of the pelvic vessels on temporal MIP images and cone-beam CT were 45 ± 19 and 69 ± 27, respectively (P < 0.01). The mean visibility score of the PA was 3.6 ± 0.6 for 4D-CT angiography and 3.97 ± 0.2 for cone-beam CT (P < 0.001). The PA was visualized in 100% of 4D-CT angiography examinations, with one PA being visible only proximally. Prostate CT perfusion analysis showed blood flow, blood volume, mean transit time, and flow extraction product values of 27.9 ± 12.5 mL/100 mL/min, 2.0 ± 0.8 mL/100 mL, 4.5 ± 0.5 second, and 12.6 ± 5.4 mL/100 mL/min, respectively, for the whole prostate gland. About half the patients showed a pronounced difference between the lobes.
Conclusions:
We introduced a CT protocol for PAE planning providing excellent visualization of the PA on temporal MIP images and 4D-CT angiography at a reasonable dose and low contrast volume. In addition, quantitative perfusion information is available, which might be useful for outcome prediction after embolization.
More Related Videos
06:04Surgical Treatment for Benign Prostatic Hyperplasia: Holmium Laser Enucleation of the Prostate HoLEP.
Published on: March 6, 2018
08:38Renal Capsule Xenografting and Subcutaneous Pellet Implantation for the Evaluation of Prostate Carcinogenesis and Benign Prostatic Hyperplasia
Published on: August 28, 2013
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Pulmonary Embolism I: Introduction
Sampling Plans
Random sampling is a method where each member of the population has an equal chance of being selected for the sample. It involves selecting individuals randomly, often using random number generators or lottery-type methods. For example, when analyzing the properties of a...
Planning Nursing Care I
Planning Nursing Care II