Related Experiment Video
Updated: Jan 23, 2026

Battery of Behavioral Tests Assessing General Locomotion, Muscular Strength, and Coordination in Mice
Published on: January 23, 2018
The Automatic Assessment of Strength and Mobility in Older Adults: A Test-Retest Reliability Study
Daniel Collado-Mateo1,2, Pedro Madeira3, Francisco J Dominguez-Muñoz4
1Faculty of Sport Science, University of Extremadura, 10003 Cáceres, Spain. danicolladom@gmail.com.
Abstract:
Background: Simple field tests such as the Timed Up and Go test (TUG) and 30 s Chair Stand test are commonly used to evaluate physical function in the elderly, providing crude outcome measures. Using an automatic chronometer, it is possible to obtain additional kinematic parameters that may lead to obtaining extra information and drawing further conclusions. However, there is a lack of studies that evaluate the test-retest reliability of these parameters, which may help to judge and interpret changes caused by an intervention or differences between populations. Thus, the aim of this study was to evaluate the test-retest reliability of the Timed Up and Go test (TUG) and 30 s Chair Stand test in healthy older adults. Methods: A total of 99 healthy older adults participated in this cross-sectional study. The TUG and the 30 s Chair Stand test were performed five times and twice, respectively, using an automatic chronometer. The sit-to-stand-to-sit cycle from the 30 s Chair Stand test was divided into two phases. Results: Overall, reliability for the 30 s Chair Stand test was good for almost each variable (intraclass correlation coefficient (ICC) >0.70). Furthermore, the use of an automatic chronometer improved the reliability for the TUG (ICC >0.86 for a manual chronometer and ICC >0.88 for an automatic chronometer). Conclusions: The TUG and the 30 s Chair Stand test are reliable in older adults. The use of an automatic chronometer in the TUG is strongly recommended as it increased the reliability of the test. This device enables researchers to obtain relevant and reliable data from the 30 s Chair Stand test, such as the duration of the sit-to-stand-to-sit cycles and phases.
More Related Videos
08:40Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019
16:11Thermochemical Studies of NiII and ZnII Ternary Complexes Using Ion Mobility-Mass Spectrometry
Published on: June 8, 2022
Related Concept Videos
Reliability and Validity
Automatic Processing and Automatic Social Behavior
Acid Strength and Molecular Structure
In the absence of any leveling effect, the acid strength of binary compounds of hydrogen with nonmetals (A) increases as the H-A bond strength decreases down a group in the periodic table. For group 17, the order of increasing acidity is HF < HCl < HBr < HI. Likewise, for group 16, the order of increasing acid strength is H2O < H2S < H2Se < H2Te. Across a row in the periodic table, the acid strength of binary hydrogen compounds increases with increasing...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Relation Between Tensile Strength and Compressive Strength of Concrete
The Equilibrium Binding Constant and Binding Strength