Comparison of impedance measured by the forced oscillation technique and pulmonary functions, including static lung
Naoya Takeichi1, Haruna Yamazaki1, Keisaku Fujimoto2
1Department of Biomedical Laboratory Sciences, Graduate School of Medicine, Shinshu University, Matsumoto, Nagano, Japan.
Abstract:
Objective: To examine whether the parameters of impedance measured by the broadband frequency forced oscillation technique (FOT) were reflected by changes in lung compliance induced by emphysema and fibrosis, we retrospectively compared the parameters of FOT and pulmonary functions, including static lung compliance (Cst), in obstructive lung disease (OLD) and interstitial lung disease (ILD). Patients and methods: The data of 18 patients with OLD (16 with COPD, two with asthma COPD overlap), 11 with ILD, and 24 healthy volunteers, whose respiratory impedance was measured using a MostGraph-01 and other pulmonary functions including Cst and lung resistance (RL) were measured on the same day and were retrospectively collected and compared. Results: The parameters of resistance, reactance, and resonant frequency showed good correlations with ventilation unevenness (r=0.63, -0.89, 0.77, respectively) and lung elastic resistance (r=0.59, -0.80, 0.73, respectively) in all groups (N=53). These indices were significant determinants of increased respiratory resistance and more negative shift of respiratory reactance (Xrs) at lower frequency (P<0.001). Decreased functional residual capacity was also a determinant of Xrs at 5 Hz (X5) (P<0.05). The differences in mean X5 in the expiratory phase relative to those in the inspiratory phase (within-breath changes in X5) were associated with airflow obstruction (P<0.002) and lung elastic resistance (P<0.001). However, no significant correlations between Cst and any parameters of respiratory impedance were observed. Conclusions: These findings suggest that the impedance parameters measured by FOT are reflected by airway obstruction, ventilation unevenness, and lung resistance, but hardly reflected by changes in lung compliance due to emphysema or fibrosis in both CLD and ILD.
Related Concept Videos
Lung Capacity
Chronic Obstructive Pulmonary Disease
Smoking is a primary risk factor for COPD, with over 80% of patients having a history of it. Patients typically experience progressive dyspnea or labored breathing, frequent coughing, and recurrent pulmonary infections. Many eventually succumb to respiratory failure, characterized by...
Chronic Obstructive Pulmonary Disease-I: Introduction
Chronic Obstructive Pulmonary Disease-V: Management
Smoking Cessation
Chronic Obstructive Pulmonary Disease-II: Pathophysiology
Chronic Inflammation
Chronic Obstructive Pulmonary Disease-V: Nursing Management
Assessment