SpO2/FiO2 as a predictor of non-invasive ventilation failure in children with hypoxemic respiratory insufficiency
Marti Pons-Odena1, Daniel Palanca1,2, Vicent Modesto3
1Pediatric Intensive Care Unit, Hospital Sant Joan de Déu, University of Barcelona, Esplugues de Llobregat, Spain.
Abstract:
Generally, monitoring of hypoxemia has been always based on partial pressure of arterial oxygen to fraction of inspired oxygen ratio; recently it was confirmed a good correlation between this ratio and a non-invasive alternative ratio of oxygen saturation to fraction of inspired oxygen (SF ratio = SpO2/FiO2). The SF ratio has been studied and validated, especially in the intubated patients, however studies monitoring patients treated with non-invasive ventilation (NIV) are lacking. The aim of the study was to determine if the SF ratio is a reliable predictive factor for failure of NIV in pediatric patients diagnosed with hypoxemic acute respiratory failure due to pneumonia. A five year retrospective study with consecutive sampling of patients diagnosed with hypoxemic acute respiratory failure due to pneumonia, admitted to the pediatric intensive care unit in a university hospital and treated with NIV was conducted. Physiological and ventilator variables were collected before starting NIV and at 2, 8 and 12 hours of treatment, and the corresponding SF ratios calculated. Thirty-four patients were studied. NIV failed in seven patients. Significant differences in SF ratio were observed between the successful and unsuccessful patients at the onset, 2 and 12 hours of treatment. Multivariable analysis revealed the SF ratio at two hours to be an independent predictor of NIV failure (odds ratio = 0.96, 95% confidence intervals 0.93-0.99; P = 0.015). Area Under Receiver Operating Characteristic curve = 0.90 (95% confidence interval = 0.79 to 1.000), optimal cut off value for SF at 2 hours ≤ 189; sensitivity = 86%, specificity = 74%. In conclusion, the SF ratio of 189 or less at 2 hours of NIV seems to be useful for predicting NIV failure in this cohort.
More Related Videos
09:24Repeated Measurement of Respiratory Muscle Activity and Ventilation in Mouse Models of Neuromuscular Disease
Published on: April 17, 2017
06:22Surfactant Depletion Combined with Injurious Ventilation Results in a Reproducible Model of the Acute Respiratory Distress Syndrome ARDS
Published on: April 7, 2021
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Acute Respiratory Failure-I
Definition: It is defined by specific criteria based on blood gas measurements. Hypoxemia happens when the partial pressure of oxygen (PaO2) falls below 60 mmHg. At the same time,...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Acute Respiratory Failure-III