Related Experiment Video
Updated: Jan 23, 2026

Robotic Cochlear Implantation for Direct Cochlear Access
Published on: June 16, 2022
Radiological evaluation of inner ear trauma after cochlear implant surgery by cone beam CT(CBCT)
Tougan Taha Abd El Aziz1, Lobna El Fiky2, Mennatallah Hatem Shalaby3
1Radiology Department, Ain Shams University, Cairo, Egypt. toganwafi@yahoo.com.
Purpose:
Cochlear implantation (CI) has been extended to involve younger age group with higher incidence of residual hearing which increases the need of minimizing surgical inner ear trauma. Radiological evaluation for electrode position has been studied yet without assessment of inner ear trauma, our objective is radiological evaluation of post cochlear implantation inner ear trauma MATERIAL AND METHODS: 20 patients with CI for pre lingual SNHL were included in this study. Cone beam CT (CBCT) was used for evaluation of electrode position and assessment of inner ear trauma. A Neuroradiologist and an implant surgeon analyzed the relation of inserted electrode to the intra-cochlear structures, with introduction of novel radiological grading for inner ear trauma.
Results:
The mean major cochlear diameter was 8.9 mm, the mean angular depth of insertion was 406.9944 (SD = 165.0559). Ten patients were with no cochlear trauma (grade 0), three patients were grade 1, two patients were grade 2 and five patients were grade 3 inner ear trauma.
Conclusion:
Radiological evaluation for electrode position should extend to involve assessment of inner ear trauma using relation of the implant to cochlear internal structures which could be performed by CBCT with high resolution and least metallic artifacts.
More Related Videos
Related Concept Videos
Radiological Investigation I: X-ray and CT
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Anatomy of the Ear
Deflection of a Beam
Singularity functions, described in an earlier lesson, are powerful mathematical tools that represent discontinuities within a function commonly encountered in structural loading...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Prismatic Beams: Problem Solving
The design begins with analyzing the beam as a free body to identify moments and force balances, thereby determining support reactions. Next, the...