Inhaler Spray Investigation Using High-Speed Phase-Contrast X-Ray and Schlieren Imaging
1Prior PLM Medical, IDA Business & Technology Park, Carrick-on-Shannon, N41 WK46, Ireland. amckiernan@priors.com.
Purpose:
The first pressurised metered dose inhaler (pMDI) was introduced in 1956. Even with excellent inhaler technique typically only 20% of the dose deposits in the lungs where needed. It is hoped that a better understanding of the initial plume formation and expansion during dose release can help improve modelling, devices and ultimately transport to the lungs. We have used two high-speed imaging techniques to investigate the transient dose event.
Methods:
Synchrotron phase-contrast X-Ray imaging is a technique that is sensitive to variations in the refractive index of materials in the X-ray region. Similarly, Schlieren imaging is an optical technique sensitive to the refractive index gradients which are often present in pMDI plumes due to gas density variations. We have combined and synchronised both techniques to investigate three commercial pMDIs actuators during dose release for various actuator/formulation combinations.
Results:
We have observed temporal phases of propellant flowing in the orifice channel. At early times flash boiling takes place and drives gas emission, steep plume density gradients and liquid jets/droplets at the orifice. Evaporating liquid is present in the sump long after the dose is finished. Regional counter-flow is seen in plumes emitted into a mouth-throat geometry.
Conclusions:
As the foamy liquid-vapour mixture is forced out of the sump and into the orifice the liquid walls of the bubbles break into fragments which are forced out of the sump and tend to form a liquid-gas flow in the orifice channel. The period of high density plume observed by the schlieren technique corresponds to flash-boiling-driven liquid exiting the orifice channel.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Radiological Investigation I: X-ray and CT
X-ray Imaging
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
Inhaled Medications
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...