New parameters of ultrafast dynamic contrast-enhanced breast MRI using compressed sensing
Maya Honda1, Masako Kataoka1, Natsuko Onishi2
1Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, Kyoto, Japan.
Background:
Ultrafast dynamic contrast-enhanced (UF-DCE) breast MRI is considered a promising method of accelerated breast MRI. However, the value of new kinetic parameters derived from UF-DCE need clinical evaluation.
Purpose:
To evaluate the diagnostic performance of the maximum slope (MS), time to enhancement (TTE), and time interval between arterial and venous visualization (AVI) derived from UF-DCE MRI using compressed sensing (CS).
Study Type:
Retrospective.
Population:
Seventy-five patients with histologically proven breast lesions. The total number of analyzed lesions was 90 (61 malignant and 29 benign).
Field Strength/Sequence:
3T MRI with UF-DCE MRI based on the 3D gradient-echo volumetric interpolated breath-hold examination (VIBE) sequence using incoherent k-space sampling combined with a CS reconstruction followed by conventional DCE MRI.
Assessment:
The diagnostic performance of the MS, TTE, AVI, and conventional kinetic analysis was analyzed and compared with histology.
Statistical Tests:
Wilcoxon rank sum test, receiver operating characteristic analysis.
Results:
The MS was larger and the TTE and AVI were smaller for malignant lesions compared with benign lesions: MS: 29.3%/s and 18.4%/s (P < 0.001), TTE: 7.0 and 12.0 seconds (P < 0.001), AVI: 2.7 and 4.4 frames (P = 0.006) for malignant and benign lesions. The discriminating power of the MS (area under the curve [AUC], 0.76) was slightly better than that of conventional kinetic analysis (AUC, 0.69) and comparable to that of the TTE and AVI (AUC, 0.78 and 0.76 for TTE and AVI, respectively). Invasive lobular carcinoma had smaller MS (21.8%/s) among malignant lesions (29.3%/s).
Data Conclusion:
The MS, TTE, and AVI can be used to evaluate breast lesions with clinical performance equivalent to that of conventional kinetic analysis. These parameters vary among histologies.
Level Of Evidence:
3 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2020;51:164-174.
Related Concept Videos
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Self-Evaluation: Self-Enhancement and Self-Verification
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Wave Parameters
Introduction to Special Senses
Tactile and Chemical Senses