Related Experiment Video
Updated: Jan 23, 2026

Bronchial Thermoplasty: A Novel Therapeutic Approach to Severe Asthma
Published on: November 4, 2010
[Distribution of airway inflammation phenotype in patients with bronchial asthma and its correlation with control
1Department of Pμlmonary and Critical Care Medicine, China-Japan Friendship Hospital, Beijing 100029, China.
Abstract:
Objective: To investigate the distribution of airway inflammation phenotypes in patients with bronchial asthma and its correlation with asthma control level. Methods: Patients who met GINA 2017 asthma diagnostic criteria from October 2017 to April 2018 in respiratory outpatient department of China-Japan Friendship Hospital were included. The clinical data of non-acute asthma patients were prospectively collected, including general data, asthma control level, pulmonary function, induced sputum cell classification, serum total IgE, exhaled nitric oxide (FeNO), blood cell classification. The correlation between phenotype distribution of airway inflammation and airway inflammation markers (eosinophils in sputum, FeNO, blood eosinophil, serum IgE) and asthma control was analyzed by correlation analysis. The correlation between sputum eosinophil level and FeNO, blood eosinophil count, serum total IgE, forced expiratory volume in one-second (FEV(1)) predicted (FEV(1)%pred) was analyzed by correlation analysis too. Results: A total of 97 asthmatic patients were enrolled. There were 38 males (39.2%) and 59 females (60.8%), aged (48±14) (range 22 to 80). Control level of asthma:13 cases (13.4%) were controlled, 39 cases(40.2%) were partially controlled and 45 cases (46.4%) were uncontrolled. The phenotypes of airway inflammation were eosinophilic 51 cases (52.6%), neutrophilic 9 cases (9.3%), mixed 35 cases (36.1%) and paucigranulocytic 2 cases (2.1%). There was no significant correlation between airway inflammation phenotype distribution, airway inflammation markers and asthma control level (P>0.05). Sputum eosinophil level was positively correlated with FeNO level in controlled and uncontrolled patients (r=0.420, P=0.008 and r=0.325, P=0.031); sputum eosinophil level was positively correlated with blood eosinophil level in uncontrolled asthma patients (r=0.328, P=0.037). There was no significant correlation between sputum eosinophil level and FEV(1)%pred (P>0.05). Conclusions: Eosinophil type is the dominant type of airway inflammation in asthmatic patients, and there is no significant correlation between airway inflammation and asthma control level. At present, airway inflammation cannot be used to assess asthma control level.
Related Concept Videos
Inflammation
Pharmacokinetics in Pediatric Patients: Drug Distribution
Correlations
Correlation and Causation
Correlation versus Causation
If the dependent variable increases or decreases when the independent variable increases, there is a positive or negative...
Pharmacokinetics in Geriatric Patients: Effect of Age on Drug Distribution
Pharmacokinetics in Obese Patients: Drug Absorption and Distribution

