Thrombus Imaging Characteristics and Outcomes in Acute Ischemic Stroke Patients Undergoing Endovascular Treatment

Bruna G Dutra1,2,3, Manon L Tolhuisen2, Heitor C B R Alves1,2,3

  • 1From the Departments of Radiology and Nuclear Medicine (B.G.D., H.C.B.R.A., K.M.T., M.K., I.G.H.J., C.B.L.M.M.), Academic Medical Center, Amsterdam, the Netherlands.

Stroke
|June 21, 2019
PubMed

Background and Purpose- Thrombus imaging characteristics have been reported to be useful to predict functional outcome and reperfusion in acute ischemic stroke. However, conflicting data about this subject exist in patients undergoing endovascular treatment. Therefore, we aimed to evaluate whether thrombus imaging characteristics assessed on computed tomography are associated with outcomes in patients with acute ischemic stroke treated by endovascular treatment. Methods- The MR CLEAN (Multicenter Randomized Clinical Trial of Endovascular Treatment for Acute Ischemic Stroke in the Netherlands) Registry is an ongoing, prospective, and observational study in all centers performing endovascular treatment in the Netherlands. We evaluated associations of thrombus imaging characteristics with the functional outcome (modified Rankin Scale at 90 days), mortality, reperfusion, duration of endovascular treatment, and symptomatic intracranial hemorrhage using univariable and multivariable regression models. Thrombus characteristics included location, clot burden score (CBS), length, relative and absolute attenuation, perviousness, and distance from the internal carotid artery terminus to the thrombus. All characteristics were assessed on thin-slice (≤2.5 mm) noncontrast computed tomography and computed tomography angiography, acquired within 30 minutes from each other. Results- In total, 408 patients were analyzed. Thrombus with distal location, higher CBS, and shorter length were associated with better functional outcome (adjusted common odds ratio, 3.3; 95% CI, 2.0-5.3 for distal M1 occlusion compared with internal carotid artery occlusion; adjusted common odds ratio, 1.15; 95% CI, 1.07-1.24 per CBS point; and adjusted common odds ratio, 0.96; 95% CI, 0.94-0.99 per mm, respectively) and reduced duration of endovascular procedure (adjusted coefficient B, -14.7; 95% CI, -24.2 to -5.1 for distal M1 occlusion compared with internal carotid artery occlusion; adjusted coefficient B, -8.5; 95% CI, -14.5 to -2.4 per CBS point; and adjusted coefficient B, 7.3; 95% CI, 2.9-11.8 per mm, respectively). Thrombus perviousness was associated with better functional outcome (adjusted common odds ratio, 1.01; 95% CI, 1.00-1.02 per Hounsfield units increase). Distal thrombi were associated with successful reperfusion (adjusted odds ratio, 2.6; 95% CI, 1.4-4.9 for proximal M1 occlusion compared with internal carotid artery occlusion). Conclusions- Distal location, higher CBS, and shorter length are associated with better functional outcome and faster endovascular procedure. Distal thrombus is strongly associated with successful reperfusion, and a pervious thrombus is associated with better functional outcome.

Related Concept Videos

Characteristics of Life01:23

Characteristics of Life

Biology is a natural science that studies life and living organisms, including their structure, function, development, interactions, evolution, distribution, and taxonomy. The field's scope is extensive and divided into several specialized disciplines, such as anatomy, physiology, ethology, genetics, and many more. All living things share a few key traits, including cellular organization, heritable genetic material and the ability to adapt/evolve, metabolism to regulate energy needs, the...
257.3K
Predicting Reaction Outcomes02:24

Predicting Reaction Outcomes

Kinetics describes the rate and path by which a reaction occurs. In contrast, thermodynamics deals with state functions and describes the properties, behavior, and components of a system. It is not concerned with the path taken by the process and cannot address the rate at which a reaction occurs. Although it does provide information about what can happen during a reaction process, it does not describe the detailed steps of what appears on an atomic or a molecular level. On the other hand,...
10.4K
Outcomes of Glycolysis01:13

Outcomes of Glycolysis

Nearly all the energy used by cells comes from the bonds that make up complex organic compounds. These organic compounds are broken down into simpler molecules, such as glucose. As a result, cells extract energy from glucose over many chemical reactions—a process called cellular respiration.
Cellular respiration can occur aerobically (with oxygen) or anaerobically (without oxygen). In the presence of oxygen, cellular respiration starts with glycolysis and continues with pyruvate...
106.8K
Characteristics of Fluids01:20

Characteristics of Fluids

When a force is applied parallel to the top surface of a solid, it resists the applied force due to the internal frictional forces between the layers of the solid known as shearing resistance. However, when the force is removed, the shearing forces restore the original shape of the solid. Other deformation forces also cause temporary changes in shape if the forces are not beyond a threshold magnitude. Solids tend to retain their shape, making the study of their rest and motion easier. Beyond...
7.9K
Characteristics of Fluids01:31

Characteristics of Fluids

Fluids differ from solids primarily in their molecular structure and stress response. Solids have tightly packed molecules with strong intermolecular forces, maintaining their shape and resisting deformation. In contrast, fluids have molecules spaced farther apart with weaker forces, allowing them to flow and deform easily.
Fluids, which include both liquids and gases, are substances that deform continuously under shearing stress. For example, water and oil are liquids with molecules that can...
990
Characteristics of BJT01:17

Characteristics of BJT

The Bipolar Junction Transistor (BJT), specifically in a common-emitter configuration, exhibits distinct current-voltage characteristics crucial for understanding its behavior in electronic circuits. These characteristics are established through experimental measurements of voltage and current relationships.
For input characteristics, the base-emitter voltage is varied, maintaining a constant collector-emitter voltage. This setup reveals a Shockley-type dependence of the collector current on...
1.3K