Assignment of Serotype-Specific IgG1, IgG2, and IgA Weight-Based Antibody Units to the Human Pneumococcal Standard

Scott Jones1, Kier Finnegan2, Jae Hee Wee2

  • 1Department of Immunobiology, UCL Great Ormond Street Institute of Child Health, NIHR Biomedical Research Centre, London, United Kingdom scott.jones@ucl.ac.uk.

Msphere
|June 21, 2019
PubMed

Insights

A new human pneumococcal standard serum (007sp) now has assigned IgA, IgG1, and IgG2 values for 11 serotypes. This ensures precise, comparable antibody measurements in diagnostic assays.

Area of Science:

  • Immunology
  • Microbiology
  • Vaccinology

Background:

  • The human pneumococcal standard reference serum, lot 89SF, was crucial for standardizing enzyme-linked immunosorbent assays (ELISA) during early pneumococcal conjugate vaccine evaluations.
  • Supplies of lot 89SF are dwindling, necessitating a replacement standard.
  • A new standard, 007sp, was established in 2011, requiring characterization for antibody quantification.

Purpose of the Study:

  • To assign weight-based serotype-specific IgA, IgG1, and IgG2 values to the 007sp reference serum.
  • To validate the accuracy of these assignments by bridging to existing values from lot 89SF.
  • To ensure comparability of antibody measurements between laboratories using the new standard.

Main Methods:

  • Assigned serotype-specific IgA, IgG1, and IgG2 values to 007sp for 11 pneumococcal serotypes by bridging to established values in lot 89SF.
  • Assessed the accuracy of assignments by comparing antibody concentrations in 16 unknown samples using both 007sp and lot 89SF as standards.
  • Utilized enzyme-linked immunosorbent assay (ELISA) methodologies for antibody quantification.

Main Results:

  • Assigned IgA, IgG1, and IgG2 values for pneumococcal serotypes 1, 3, 4, 5, 6B, 7F, 9V, 14, 18C, 19F, and 23F to the 007sp standard.
  • Serotype-specific IgA, IgG1, and IgG2 concentrations in 007sp were comparable to those in lot 89SF.
  • High correlation (average R² > 0.97) was observed when comparing antibody values in unknown samples using 007sp versus lot 89SF, demonstrating precision.

Conclusions:

  • The new 007sp human pneumococcal standard serum is well-characterized for IgA, IgG1, and IgG2 antibody quantification.
  • The assigned values ensure accurate and reproducible antibody measurements, critical for vaccine efficacy studies and diagnostics.
  • Further studies are needed to assign IgM values due to observed nonparallelism between standards.

Related Concept Videos

Measurement: Standard Units03:38

Measurement: Standard Units

Every measurement provides three kinds of information: the size or magnitude of the measurement (a number), a standard of comparison for the measurement (a unit), and an indication of the uncertainty of the measurement. While the number and unit are explicitly represented when a quantity is written, the uncertainty is an aspect of the errors in the measurement results.
78.7K
Units and Standards of Measurement01:10

Units and Standards of Measurement

A physical quantity is defined either by specifying its measurement method or by stating how it is calculated from other measurements. For example, consider a metallic cube. We might define its mass and dimensions by specifying methods for measuring them, such as using a weighing machine and a meter scale. Then, we could define the volume by stating that it is the cube of its side, and we could calculate the density as the mass divided by the volume.
Measurements of physical quantities are...
44.6K
Density, Specific Weight, Specific Gravity and Compressibility of Fluid01:27

Density, Specific Weight, Specific Gravity and Compressibility of Fluid

Density, specific weight, specific gravity, and compressibility are fundamental properties of fluids. Density is the mass per unit volume, characterizing the mass of a fluid system. It influences buoyancy, pressure, flow dynamics, viscosity, thermal conductivity, and sound propagation. For instance, in pipeline design, accurate density measurements ensure that the pipeline can handle the fluid's mass.
Specific weight represents the weight per unit volume and is calculated by multiplying...
1.5K
Measurement: Derived Units03:02

Measurement: Derived Units

The International System of Units or SI system, by international agreement, has fixed measurement units for seven fundamental properties: length, mass, time, temperature, electric current, amount of substance, and luminosity. These are called the SI base units.
54.5K
Standard Enthalpy of Formation02:37

Standard Enthalpy of Formation

Enthalpy changes are typically tabulated for reactions in which both the reactants and products are at the same conditions. A standard state is a commonly accepted set of conditions used as a reference point for the determination of properties under other different conditions. For chemists, the IUPAC standard state refers to materials under a pressure of 1 bar and solutions at 1 M and does not specify a temperature. Many thermochemical tables list values with a standard state of 1 atm. Because...
49.0K
Weighted Mean00:57

Weighted Mean

While taking the arithmetic, geometric, or harmonic mean of a sample data set, equal importance is assigned to all the data points. However, all the values may not always be equally important in some data sets. An intrinsic bias might make it more important to give more weightage to specific values over others.
For example, consider the number of goals scored in the matches of a tournament. While computing the average number of goals scored in the tournament, it may be more important to...
6.2K