Related Experiment Video
Updated: Jan 23, 2026

Voluntary Breath-hold Technique for Reducing Heart Dose in Left Breast Radiotherapy
Published on: July 3, 2014
Pseudo skin flash on VMAT in breast radiotherapy: Optimization of virtual bolus thickness and HU values
María Lizondo1, Artur Latorre-Musoll1, Montserrat Ribas1
1Servei de Radiofísica i Radioprotecció, Hospital de la Santa Creu i Sant Pau, Sant Antoni Maria Claret 167, Barcelona 08025, Spain.
Purpose:
Optimisation strategies for volumetric modulated arc therapy (VMAT) in most treatment planning systems for breast cancer do not account for patient positioning, breathing, or anatomical changes. To overcome this limitation, a pseudo-skin flash strategy using a virtual bolus has been proposed. Using this strategy, we determined optimal thickness and value of Hounsfield units (HU) assigned to the virtual bolus to ensure adequate CTV irradiation.
Materials And Methods:
We modified the original computed tomography data (CT0) by adding combinations of thicknesses and densities of a virtual bolus on PTVs (CT') of seven bilateral breast cancer patients. Using a single optimization objective template, we obtained a VMAT plan on CT' and recalculated this on the CT0. Optimal CT' parameters were defined as those that minimized dose differences between CT' and CT0 plans regarding PTV and OAR dose-volume parameters. We studied bolus parameters regarding robustness by shifting the isocenter 5 and 10 mm in the breathing direction for each CT0 plan.
Results:
The minimal dosimetric impact was between -400 and -600 HU depending on bolus thickness. OARs doses were not significantly affected. Best robustness was found for -500 HU and 15 mm bolus thickness against shifts of up to 10 mm in the breathing direction.
Conclusion:
Our results support a bolus thickness equal to the CTV-PTV margin plus 5 mm and a virtual bolus HU value around -500 and -400 depending on the bolus thickness chosen. These findings could play a useful role in maximisingrobustness and minimising the need for plan renormalization.
Related Concept Videos
Biodiversity and Human Values
Professional Values
The values that are the foundation of the nursing profession are altruism, autonomy, human dignity, and social justice.
First, altruism refers to the concern for the welfare and well-being of others without personal...
Critical Values
z Scores and Unusual Values
This score indicates how far a value is from the mean in terms of standard deviation. For example, if a data value has a z score of +1, the researcher can infer that the particular data value is one standard deviation above the mean. If another data...
Absolute and Local Extreme Values
Virtual Work
In static equilibrium, a body can experience an imaginary or virtual movement, such as displacement or rotation. The virtual work done by a force is equal to the dot product of force and virtual displacement in the direction of the force. When it comes to virtually rotating a...

