Related Experiment Video
Updated: Jan 23, 2026

Using Q Suture to Enhance Resistance to Gap Formation and Tensile Strength of Repaired Flexor Tendons
Published on: June 3, 2020
Biomechanical comparison of three epitendinous suture patterns as adjuncts to a core locking loop suture for repair
Christina J Cocca1, Daniel J Duffy2, Mariana E Kersh3
1Department of Veterinary Clinical Medicine, College of Veterinary Medicine, University of Illinois, Urbana, Illinois.
Objective:
To determine the effects of different epitendinous sutures (ES) in addition to core locking-loop (LL) sutures on the mechanical properties and gap formation in a canine cadaveric tendon model.
Study Design:
Experimental, ex vivo, biomechanical study.
Sample Population:
Seventy-two cadaveric superficial digital flexor tendon specimens.
Methods:
Superficial digital flexor tendon specimens were divided into four groups (n = 18): sharply transected and repaired with LL, LL + simple continuous ES, LL + Silfverskiöld cross-stitch ES, and LL + interlocking horizontal mattress ES. Constructs were loaded to monotonic failure. Failure modes, gapping, yield, peak, and failure forces were analyzed. Significance was set at P < .05.
Results:
Yield, peak, and failure forces increased by 2.5-fold, two-fold, and twofold, respectively when ES groups were compared with core LL suture patterns alone (P < .0001). Resistance to 1- and 3-mm gap formation was greater in ES groups compared with core LL constructs alone (P < .0001). No differences in yield, peak, failure force, or gapping were observed among ES patterns (P > .827).
Conclusion:
Adding an ES reduced gap formation and increased yield, peak, and failure forces of tenorrhaphies. No difference was detected between the epitendinous patterns tested in this study.
Clinical Significance:
The addition of an ES seems more relevant than the specific type of pattern to improve the biomechanical properties of flexor tendon repairs. In vivo studies are warranted to determine the biological implications of the patterns tested here.
Related Concept Videos
Sutures of the Skull
Sutures are immobile joints between adjacent bones of the skull. The narrow gap between the bones is filled with dense, fibrous connective tissue that unites the bones. The long sutures located between the skull bones are not straight but instead follow irregular, tightly twisting paths. These twisting lines tightly...
The Nucleosome Core Particle
The paradox
Nucleosomes, paradoxically, perform two opposite functions simultaneously. On the one hand, their main responsibility is to protect the delicate DNA strands from physical damage and help achieve a higher compaction ratio. While on the other hand, they must allow polymerase enzymes to access DNA...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Mismatch Repair
Heart Failure VI: Adjunct Therapies

