Related Experiment Video
Updated: Jan 23, 2026

'Bioluminescent' Reporter Phage for the Detection of Category A Bacterial Pathogens
Published on: July 8, 2011
Reporting categories in urine test strip analysis: Croatian survey and call for action
Ana Dojder1, Dora Vuljanić1, Valentina Špoljarić1
1Department of Medical Laboratory Diagnostics, University Hospital "Sveti Duh", Zagreb, Croatia.
Introduction:
In line with the national recommendations, Croatian medical laboratories report urine test strip qualitative analysis results using a categorized scale with defined number of categories. Since concentration ranges for measured analytes have not been provided by national professional authority, it is up to the laboratories to define their own categories. The aim of study was to assess the comparability of concentrations assigned to different categories used in reporting the results of dipstick urinalysis in Croatian laboratories.
Material And Methods:
A questionnaire was e-mailed to all Croatian medical laboratories (N = 195). They were asked to provide the number of categories and respective concentrations for each parameter. Data were described as numbers and percentages. Values above the upper reference range limit, which were assigned as normal and/or trace category, were considered as false negative.
Results:
Response rate was 71% (139/195). Seventy percent (98/139) of laboratories report their results with either higher (77/98; 79%) or lower (2/98; 2%) number of categories, relative to the national recommendation, whereas 19/98 (19%) report their results as concentrations. Great heterogeneity of reporting categories was observed. Multiple categories were assigned to same concentrations and there was a large overlap of concentrations for most categories. Considerable proportion of laboratories reported false negative results for ketones (42%), leukocytes (30%) and glucose (21%).
Conclusions:
The concentrations assigned to categories used to report the results of dipstick urinalysis are not comparable among Croatian medical laboratories. There is an urgent need for harmonization and standardization of reporting the results of urine dipstick analysis in Croatia.
Related Concept Videos
Surveys
Filtration and Urine Formation
Introduction to Surveying, Plane Surveying and Geodetic Surveys
Categories of Equilibrium
One of the categories of equilibrium is collinear equilibrium, which involves forces acting along a straight line. This type of equilibrium requires only one force equation in the direction of the forces, as the other equations are...
Urine Studies II: Urine Culture and Sensitivity Test
Types of Surveys

