High-sensitivity cardiac Troponin T delta concentration after repeat pulmonary vein isolation

Ivan Zeljkovic1, Sven Knecht1,2, Florian Spies1,2

  • 1Cardiology Department, University Hospital Basel, University of Basel, Basel, Switzerland.

Biochemia Medica
|June 22, 2019
PubMed

Insights

High-sensitivity cardiac troponin T (hs-cTnT) changes after repeat pulmonary vein isolation (PVI) do not predict atrial fibrillation recurrence. Measuring hs-cTnT after repeat PVI offers no additional outcome information.

Area of Science:

  • Cardiology
  • Electrophysiology
  • Biomarkers

Background:

  • Myocardial injury after ablation procedures can be assessed by changes in high-sensitivity cardiac troponin T concentrations (hs-cTnT).
  • Atrial fibrillation (AF) recurrence is a concern after pulmonary vein isolation (PVI).

Purpose of the Study:

  • To evaluate the prognostic value of hs-cTnT delta concentrations in predicting AF recurrence following repeat PVI.
  • To determine if hs-cTnT measurements provide additional clinical information after repeat PVI.

Main Methods:

  • A cohort of 105 patients with paroxysmal AF undergoing repeat PVI were studied.
  • Hs-cTnT levels were measured pre-procedure and 18-24 hours post-procedure.
  • Follow-up at 3, 6, and 12 months assessed AF recurrence, with Cox-regression analysis for predictors.

Main Results:

  • AF recurred in 23% of patients after a median 12-month follow-up.
  • A weak correlation was found between radiofrequency energy delivery time and hs-cTnT delta (R² = 0.31, P = 0.030).
  • Hs-cTnT delta was not a significant predictor of long-term AF recurrence after repeat PVI (P = 0.920).

Conclusions:

  • This study indicates that hs-cTnT delta does not predict AF recurrence after repeat PVI.
  • Routine hs-cTnT measurement post-repeat PVI does not enhance outcome prediction.
Abstract

Related Concept Videos

The Delta-to-Delta Circuit01:17

The Delta-to-Delta Circuit

In a delta-delta configuration, the source and the load are connected in a delta manner, forming a closed loop that divides the network into three distinct phases. This configuration makes the phase voltages identical to line voltages. Assuming the sources are in positive sequence, the phase voltages can be expressed directly without having a neutral wire.
1.1K
The Y-to-Delta Circuit01:19

The Y-to-Delta Circuit

A balanced wye-to-delta circuit comprises balanced Y-connected voltage sources and delta-connected loads with no neutral line connection.
The initial step in analyzing a wye-to-delta circuit is to assume a positive phase sequence. These phase voltages are then utilized to calculate the line voltages that occur directly across the delta-connected load impedances. Van, Vbn, and Vcn are the phase voltages in wye, and Vab, Vbc, and Vca are the line voltages for a delta circuit. The relation between...
700
The Delta-to-Y Circuit01:16

The Delta-to-Y Circuit

In the delta-wye circuit, the source is delta-connected, while the load is in a wye configuration. This means that the phase voltage of the delta-connected source is equal to the line voltage of the wye-connected load. The connection between two-line currents originates from the delta-connected source. The phase difference in the balanced system allows for calculating one line current given the other, utilizing the positive sequence of phases. In the delta-wye system, the phase currents in the...
857
Concentration Cells02:41

Concentration Cells

A concentration cell is a type of a  voltaic cell constructed by connecting two almost identical half-cells, both based on the same half-reaction and using the same electrode, differing only in the concentration of one redox species. A concentration cell's potential, therefore, is determined only by the concentration difference of the particular redox species.
Consider the following voltaic cell:
25.6K
Veins01:17

Veins

Veins are an integral part of our circulatory system, serving as the blood vessels that transport blood from all body regions to the heart. They are a network of hollow tubes that carry blood low in oxygen from the body's cells back to the heart for reoxygenation. Veins are crucial for maintaining the body's overall fluid balance and the continuous circulation of blood.
Structure of Veins:
The structure of veins is specifically designed to assist in the low-pressure transportation of...
8.4K
Solution Concentration and Dilution02:59

Solution Concentration and Dilution

The relative amount of a given solution component is known as its concentration. Often, though not always, a solution contains one component with a concentration that is significantly greater than that of all other components. This component is called the solvent and may be viewed as the medium in which the other components are dispersed or dissolved. Solutions in which water is the solvent are, of course, very common on our planet. A solution in which water is the solvent is called an aqueous...
127.6K