Related Experiment Video
Updated: Jan 23, 2026

Brain Mapping Using a Graphene Electrode Array
Published on: October 20, 2023
Building electrode with three-dimensional macroporous interface from biocompatible polypyrrole and conductive
Liming Yang1, Genping Yi1, Yanan Hou2
1Key Laboratory of Jiangxi Province for Persistent Pollutants Control and Resources Recycle, Nanchang Hangkong University, Nanchang, 330063, PR China.
Abstract:
Bioelectrochemical systems (BESs) possess a great potential for simultaneous wastewater treatment and energy recovery. Rational construction of electrode materials could significantly improve the BESs performance. Three-dimensional macroporous electrode interface with high conductivity is highly desirable but challenging. In this work, we report a hierarchically nanostructured reduced graphene oxide nanosheets-polypyrrole (rGO@PPy) electrode via one-step electrodeposition technique. The prepared electrode was comprehensively studied by scanning/transmission electron microscopy, Raman spectroscopy, X-ray diffraction and electrochemical measurements, which showed that the rGO@PPy possessed a three-dimensional macroporous interconnecting scaffold with superior conductivity. The rGO@PPy electrode was utilized in Geobacter sulfurreducens inoculated BESs, and the maximum current density was 4.10 ± 0.02 mA cm-2, which is 8-fold higher than that of a rGO electrode (0.51 ± 0.03 mA cm-2), and is among the best performance reported for two-dimensional electrodes. The improved performance is ascribed to ultrahigh biomass concentration induced by "best match scale" between rGO@PPy and microbes, excellent extracellular electron transfer, as well as enhanced microbial affinity through the adequate exposure of biocompatible PPy layers. This work demonstrated a synergistic effect between rGO and PPy for the BESs performance improvement, and provided a new insight to design and fabricate a high-performance bioelectrode.
Related Concept Videos
Protein-protein Interfaces
Standard Electrode Potentials
Conduct Disorder
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Conduction System of the Heart
This system relies on the unique properties of nodal and Purkinje cells:...
Movement Joints in Buildings
The simplest type of movement joints, working joints, are...

