Related Experiment Video
Updated: Jan 23, 2026

Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
Electrocardiographic and clinical predictors of permanent pacemaker insertion following Perceval sutureless aortic
Giacomo Mugnai1, Darragh Moran1, Jan Nijs2
1Heart Rhythm Management Centre, UZ Brussel-VUB, Brussels, Belgium.
Background:
Sutureless aortic valve replacement surgery (AVR) is a reasonable alternative surgical approach in those patients with aortic stenosis who would benefit from reduced cross clamp time, such as elderly and high-risk patients. We sought to evaluate the incidence of pacemaker (PM) implantation following sutureless AVR and to analyse possible pre-operative electrocardiographic and clinical predictors of PM implantation.
Methods And Results:
Between November 2013 and March 2015, 58 patients (male 43%, age 77.9 ± 4.9 years) having undergone sutureless AVR with a Perceval prosthesis (Sorin Biomedica Cardio Srl, Saluggia, Italy) were taken into consideration for our analysis. During a mean follow up of 13.8 ± 5.0 months (median 13 months), 14 patients (24.1%) underwent pacemaker (PM) implantation following sutureless AVR procedure. Among these patients, 12 (86%) presented III degree atrioventricular (AV) block, 1 (7%) presented II degree AV block, and remaining one (7%) severe symptomatic bradycardia. The comparison of pre-operative characteristics between PM group and no PM group highlighted that QRS duration, EuroSCORE II index and chronic renal dysfunction were significantly associated with the development of AV conduction abnormalities/symptomatic bradycardia requiring PM implantation (respectively, p = 0.01, p = 0.02 and p = 0.03).
Conclusions:
The incidence of PM implantation after sutureless AVR was 24.1% in the present study. The EuroSCORE II, QRS duration and renal dysfunction were significantly associated with higher risk of AV conduction abnormalities/symptomatic bradycardia requiring PM placement.
Related Concept Videos
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Mitral Valve Prolapse I: Introduction
Aortic Regurgitation I: Introduction
Nursing Clinical Information System
A Nursing Clinical Information System (NCIS) is a specialized type of healthcare information system tailored to meet the unique needs of nursing practice. It incorporates the principles of nursing informatics to streamline information management and improve the quality of care delivery.
Critical attributes of NCIS include:
Clinical Trials
There are four phases in a clinical trial. A phase one...