Related Experiment Video
Updated: Jan 23, 2026

Development of Metarhizium anisopliae as a Mycoinsecticide: From Isolation to Field Performance
Published on: July 30, 2017
TRASE 1D sequence performance in imperfect B1 fields
Pallavi Bohidar1, Hongwei Sun2, Gordon E Sarty1
1Space MRI Lab, Division of Biomedical Engineering, University of Saskatchewan, Saskatoon, Canada.
Abstract:
Transmit Array Spatial Encoding (TRASE) is an MRI technique that uses radio-frequency (RF) magnetic field (B1) phase gradients for spatial encoding. A TRASE pulse sequence consists of a long echo train in which each echo samples a different k-space point. Due to the need for accurate refocusing, TRASE imaging performance depends on |B1| homogeneity. Although the CPMG echo train is often relied on to provide immunity against B1 flip angle errors, this does not apply to TRASE echo trains. Due to the spatially dependent B1 phases involved in TRASE imaging, the CPMG condition, where all spins flip about the y-axis in the rotating frame, can only be achieved at one single location within the sample. Moreover, CPMG only preserves one component of the transverse magnetization, the y-component, whereas TRASE requires both components to be retained. Here we investigate the performance of a set of variants of a 1-dimensional (1D) TRASE sequence under conditions of |B1| errors. We varied the B1 transmit pulse RF waveform phases in an effort to optimize the TRASE imaging point spread function (PSF). The performance of 256 sequence variants, including those previously reported in the literature was studied. Both Bloch equation simulations and experimental confirmations were completed. Off-resonance (B0 inhomogeneity) effects were not considered so that the effects of B1 inhomogeneity alone could be understood. Results show that, using optimum transmit pulse phases, high quality image encoding is achievable over ∼90% of the Nyquist field-of-view (FOV) for a practically realizable variation in B1 amplitude (Δ|B1|⩽±11%). This improves significantly upon the performance of a previously-reported sequence which generated ∼75% usable FOV within the Nyquist FOV.
Related Concept Videos
Cis-regulatory Sequences
Sanger Sequencing
Electric Field
In the new picture, imagine that the first charge sets up an electric field independent of all other charges in the universe. When another charge comes in its vicinity, the second charge experiences an electric force depending on the electric field at that point. The source charge does not...
Magnetic Fields
A magnetic field is defined by the force that a charged particle experiences...
Electromagnetic Fields
However, the observation of...
Field Effect Transistor

