Related Experiment Video
Updated: Jan 23, 2026

Separation and Fractionation of Culture Filtrate Proteins (CFPs) from Mycobacterium tuberculosis
Published on: July 11, 2025
Methods for one- and two-dimensional gas chromatography with flame ionization detection for identification of
Fatma Nur Arslan1, Arend Kolk2, Hans-Gerd Janssen3
1Department of Chemistry, Faculty of Science, University of Karamanoglu Mehmetbey, P.O. Box 70100, Karaman, Turkey; University of Amsterdam, Van't Hoff Institute for Molecular Sciences, Analytical Chemistry-Group, P.O. Box 94157, 1090 GD Amsterdam, the Netherlands.
Abstract:
Two simplified methods based on manual thermally-assisted hydrolysis and methylation (THM) GC and GC × GC with flame ionization detection (FID) were developed for the detection of mycobacteria and Mycobacterium tuberculosis (MTB) in sputum. A central composite design was employed to optimize the THM derivatization conditions. For the detection of MTB the known mycobacterial markers tuberculostearic acid (TBSA) and hexacosanoic acid (C26), as well as three MTB specific markers, the mycocerosates, were evaluated. We found that the optimum conditions for THM release of TBSA and C26 differ from those for maximum release of the mycocerosates. Higher reagent volumes, higher temperatures and longer incubation increase the mycocerosates yield. Application of these conditions unfortunately resulted in unacceptable safety hazards. A GC × GC-FID method was developed that allowed accurate detection of mycocerosates even at poor conversion yields of the derivatization reaction. Using spiked sputum samples from non-TB patients, the detection limit of the method based on TBSA and C26 was found to be comparable to that of microscopy, i.e. 104-105 bacteria/mL sputum. To validate the new test, we compared the results we found for fifteen sputum samples from patients from South Africa suspected of having tuberculosis with those of culture, the gold standard method. Based on the presence of TBSA and C26, all eight microscopy and culture positive samples, and even two microscopy negative but culture positive samples were positive by THM-GC-FID. All five microscopy and culture negative sputum samples were also negative for THM-GC-FID, giving a specificity of 100%. Using GC × GC-FID we could detect mycocerosates, the specific markers for MTB in seven out of ten MTB culture positive sputum samples. The five culture negative cases were also negative for mycocerosates in manual THM-GC × GC-FID giving again 100% specificity. The results obtained indicate that the new methods hold great potential for the early diagnosis of TB in developing countries.
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Ionization Energy
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...

