Related Experiment Video
Updated: Jan 23, 2026

Ultrasound Based Assessment of Coronary Artery Flow and Coronary Flow Reserve Using the Pressure Overload Model in Mice
Published on: April 13, 2015
Diagnostic accuracy of 3D deep-learning-based fully automated estimation of patient-level minimum fractional flow
Kanako K Kumamaru1, Shinichiro Fujimoto2, Yujiro Otsuka1,3
1Department of Radiology, Juntendo University, 2-1-1 Hongo, Bunkyo-ku, Tokyo 113-8421, Japan.
Aims:
Although deep-learning algorithms have been used to compute fractional flow reserve (FFR) from coronary computed tomography angiography (CCTA), no study has achieved 'fully automated' (i.e. free from human input) FFR calculation using deep-learning algorithms. The purpose of the study was to evaluate the accuracy of a fully automated 3D deep-learning model for estimating minimum FFR from CCTA data, with invasive FFR as the reference standard.
Methods And Results:
This retrospective study of 1052 patients included 131 patients whose CCTA studies showed 30-90% stenosis and underwent invasive FFR (abnormal FFR observed in 72/131, 55%), and 921 patients who underwent clinically indicated CCTA without invasive FFR. We designed a fully automated 3D deep-learning model that inputs CCTA data and outputs minimum FFR without requiring human input. The model comprised a series of deep-learning algorithms: a conditional generative adversarial network, a 3D convolutional ladder network, and two independent neural networks with integrated virtual adversarial training. We used Monte Carlo cross-validation to evaluate the accuracy of the model for estimating FFR, with invasive FFR as the reference standard. The deep-learning FFR achieved area under the receiver-operating characteristic curve of 0.78 for detection of abnormal FFR; and was significantly higher than for visually determined CCTA >50% stenosis (area under the curve = 0.56). The deep-learning FFR model achieved 76% accuracy for detecting abnormal FFR, with sensitivity of 85% (79-89%) and specificity of 63% (54-70%).
Conclusion:
The 3D deep-learning model, which performs fully automatic estimation of minimum FFR from cardiac CT data, achieved 76% accuracy in detecting abnormal FFR.
More Related Videos
04:48Application of Deep Learning-Based Medical Image Segmentation via Orbital Computed Tomography
Published on: November 30, 2022
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Acute Coronary Syndrome III: Diagnostic Studies
Imaging Studies III: Computed Tomography
Improving Translational Accuracy
Improving Translational Accuracy
Uncertainty in Measurement: Accuracy and Precision