Thoracic kyphosis assessment in postmenopausal women: an examination of the Flexicurve method in comparison to radiological methods
Related Experiment Video
Updated: Jan 23, 2026

Design and Implementation of an fMRI Study Examining Thought Suppression in Young Women with, and At-risk, for Depression
Published on: May 19, 2015
Abstract:
The Flexicurve ruler is an alternative method to radiographs for measuring thoracic kyphosis (curvature), but it is not certain that it is comparable. This study shows that Flexicurve can estimate radiographic vertebral centroid angles with less error than Cobb angles but that its accuracy would be inadequate for most clinical purposes.
Introduction:
The Flexicurve ruler provides a non-radiological method of measuring thoracic kyphosis (TK) that has moderately strong correlations with the gold-standard radiographic Cobb angle method, while consistently underestimating the TK angle. Cobb angles can include measurement errors that may contribute to poor agreement, particularly in older populations. The vertebral centroid angle could be a better radiographic reference method for the validation of Flexicurve. Using two separate radiographic measurements of TK, we examined the validity of Flexicurve. We aimed to ascertain the level of agreement between measures and to empirically explore reasons for between-method differences.
Methods:
TK angles determined using Flexicurve and radiographic Cobb and vertebral centroid methods were compared using data from 117 healthy postmenopausal women (mean (SD) age 61.4 (7.0) years). Bland and Altman plots were used to assess differences between methods. Age, bone mineral density and body mass index were examined as characteristics that might explain any differences.
Results:
Flexicurve angles were scaled prior to analysis. There was no statistically significant difference between angles produced by Flexicurve and vertebral centroid methods (MD - 2.16°, 95%CI - 4.35° to 0.03°) although differences increased proportionally with TK angles. Flexicurve angles were significantly smaller than radiographic Cobb angles and depending on the scaling method used, systematic error ranged between - 2.48° and - 5.19°. Age accounts for some of the differences observed (R2 < 0.08, p < 0.005).
Conclusions:
TK measured using the Flexicurve shows better agreement with the radiographic vertebral centroid method, but inaccuracy of the Flexicurve increases with increasing angle of kyphosis.
More Related Videos
Related Concept Videos
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
Thoracic Aorta
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Radiological Investigation I: X-ray and CT
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:

