Related Experiment Video
Updated: Jan 23, 2026

How to Build a Laser Speckle Contrast Imaging LSCI System to Monitor Blood Flow
Published on: November 11, 2010
Interobserver reliability of laser speckle contrast imaging in the assessment of burns
Robin Mirdell1, Simon Farnebo1, Folke Sjöberg1
1Department of Clinical and Experimental Medicine, Faculty of Health Sciences, Linköping University, Linköping, Sweden; Department of Plastic Surgery, Hand Surgery, and Burns, Linköping University, Linköping, Sweden.
Objectives:
Laser speckle contrast imaging (LSCI) is an emerging technique for the assessment of burns in humans and interobserver differences have not been studied. The aim of this study was to compare assessments of perfusion images by different professional groups regarding (i) perfusion values and (ii) burn depth assessment.
Methods:
Twelve observers without LSCI experience were included. The observers were evenly recruited from three professional groups: plastic surgeons with experience in assessing burns, nurses with experience in treating burns, and junior doctors with limited experience of burns. Ten cases were included. Each case consisted of one digital photo of the burn with a pre-marked region of interest (ROI) and two unmarked perfusion images of the same area. The first and the second perfusion image was from 24h and 72-96h after injury, respectively. The perfusion values from both perfusion images were used to generate a LSCI recommendation based on the perfusion trend (the derivative between the two perfusion values). As a last step, each observer was asked to estimate the burn depth using their clinical experience and all available information. Intraclass correlation (ICC) was calculated between the different professional groups and among all observers.
Results:
Perfusion values and perfusion trends between all observers had an ICC of 0.96 (95% CI 0.91-0.99). Burn depth assessment by all observers yielded an ICC of 0.53 (95% CI: 0.31-0.80) and an accuracy of 0.53 (weighted kappa). LSCI recommendations generated by all observers had an ICC of 0.95 (95% CI: 0.90-0.99).
Conclusion:
Observers can reliably identify the same ROI, which results in observer-independent perfusion measurements, irrespective of burn experience. Extensive burn experience did not further improve burn depth assessment. The LSCI recommendation was more accurate in all professional groups. Introducing LSCI measurements would be likely improve early assessment of burns.
More Related Videos
07:20A Novel Approach to Overcome Movement Artifact When Using a Laser Speckle Contrast Imaging System for Alternating Speeds of Blood Microcirculation
Published on: August 30, 2017
06:24Paired Cisterna Magna Nanoinjection and Laser Speckle Contrast Imaging Assay to Study Cerebral Blood Flow Regulation In Vivo
Published on: July 8, 2025
Related Concept Videos
Reliability and Validity
Burn Injuries
The damage results in the death of skin cells, which can lead to a massive loss of fluid. Dehydration, electrolyte imbalance, and renal and circulatory failure follow, which can be fatal. Burn patients are treated with intravenous fluids to offset...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Distribution Reliability and Automation
Matrix-Assisted Laser Desorption Ionization (MALDI)
Assessment of the Mouth
Mouth Inspection
The inspection begins with visually examining the mouth for symmetry, color, and size.